Control management: INBOUND and OUTBOUND ports and protocols used by the system
Application /Functionality INBOUND ports on the con‐
troller: protocol
OUTBOUND ports from the
controller: protocol
PING IPv4 ICMPv4
PING IPv6 ICMPv6
nslookup UDP local port : any
UDP remote port : 53
SNMP based applications UDP 161: SNMP
Name resolution Outgoing connection:
Local port (on controller):
UDP(/TCP) <dynamic value>
Remote port (on DNS server):
UDP(/TCP) 53
Océ Express WebTools TCP 80: HTTP
TCP 443: HTTPS
Océ Account Center TCP 80: HTTP
Accounting information re-
trieval
TCP 80: HTTP
User authentication by user
name and password
TCP 88 /UDP 88: Kerberos
TCP 389 /UDP 389: LDAP
User authentication by smart
card
TCP 80: OCSP
TCP 80: HTTP or TCP 443:
HTTPS
Océ Meter Manager UDP 161: SNMP
Océ back-channel TCP 65200 for OCI back-chan-
nel
Océ Remote Service TCP 443: HTTPS
TCP web proxy port
(1)
NetBios over TCP/IP UDP 137 TCP 139, 445
UDP 138
WSD TCP 80: HTTP
UDP 3702 for WSD discovery
TCP 5357 for WSD eventing
WAVE TCP 80: HTTP
OBIS TCP 80: HTTP for back-channel
(Océ Publisher Select)
IPsec UDP 500
UDP 4500
Notes:
(1)
When there is a proxy.
Additional built-in Windows firewall rules