Time(s) *1 Ink absorber
0 times Main ink absorber (0%)
1 time Platen ink absorber (0%)
2 times Both the main and platen ink absorbers (0%)
3 times or more Press the ON/OFF button to return to the ink amount resetting mode.
3) Press the ON/OFF button to specify the ink absorber whose value should be reset to 0%.
4) After the ink absorber counter is reset, the counter value is printed automatically.
("D=000.0 Ps=000.0" is printed at the top left of the paper.)
*1: According to the number of times the Stop/Reset button is pressed, the LED lights as follows:
- Odd number of times: Alarm LED lights
- Even number of times: ON/OFF LED lights
<Destination settings>
In the destination settings mode, press the Stop/Reset button the specified number of time(s) according to
the destination listed in the table below, and press the ON/OFF button.
Time(s) LED indication Destination
0 times Green (Power) No change of the destination
1 time Orange (Alarm) Japan
2 times Green (Power) Korea
3 times Orange (Alarm) US
4 times Green (Power) Europe
5 times Orange (Alarm) Australia
6 times Green (Power) Asia
7 times Orange (Alarm) China
8 times Green (Power) Taiwan
9 times Orange (Alarm) Latin America
10 times Green (Power) Brazil
11 times Orange (Alarm) Canada
12 times or more Green (Power) Return to the destination selection
Note: After setting the destination, confirm the model name and destination in service test print or EEPROM
information print.
(13/32)