the control channel or further, causing T1 time-over
##750 TX After transmitting PPS-NULL in ECM transmission, no significant
signal has been received, and re-transmission of the procedure
signal has been attempted the number of specified times but failed.
##752 TX After transmitting PPS-NULL in ECM transmission, DCN has been
received.
##753 TX After transmitting PPS-NULL in ECM transmission, re-transmission of
the procedure signal has been attempted the number of specified
times but failed, or T5 time-over (60 sec.) has occurred.
##754 TX After transmitting PPS-NULL in ECM transmission, re-transmission of
the procedure signal has been attempted the number of specified
times but failed.
##755 TX After transmitting PPS-MPS in ECM transmission, no significant
signal has been received, and re-transmission of the procedure
signal has been attempted the number of specified times but failed.
##757 TX After transmitting PPS-MPS in ECM transmission, DCN has been
received.
##758 TX After transmitting PPS-MPS in ECM transmission, re-transmission of
the procedure signal has been attempted the number of specified
times but failed, or T5 time-over (60 sec.) has occurred.
##759 TX After transmitting PPS-MPS in ECM transmission, re-transmission of
the procedure signal has been attempted the number of specified
times but failed.
##760 TX After transmitting PPS-EOM in ECM transmission, no significant
signal has been received, and re-transmission of the procedure
signal has been attempted the number of specified times but failed.
##762 TX After transmitting PPS-EOM in ECM transmission, DCN has been
received.
##763 TX After transmitting PPS-EOM in ECM transmission, re-transmission of
the procedure signal has been attempted the number of specified
times but failed, or T5 time-over (60 sec.) has occurred.
##764 TX After transmitting PPS-EOM in ECM transmission, re-transmission of
the procedure signal has been attempted the number of specified
times but failed.
##765 TX After transmitting PPS-EOP in ECM transmission, no significant
signal has been received, and re-transmission of the procedure
signal has been attempted the number of specified times but failed.
##767 TX After transmitting PPS-EOP in ECM transmission, DCN has been
received.
##768 TX After transmitting PPS-EOP in ECM transmission, re-transmission of
(8/32)