SmartLock
®
Controller Page 19 of 26
Installation Manual Nov 2018 • Rev. 3.2
Output Wiring
DOOR OPERATOR, FORCED ENTRY, DOOR-HELD-OPEN
Use dry contact relays.
NOTE: Maximum power through any of these relays is 30 VDC at 1 A.
NOTE: Door Operator requires momentary closure to activate relay.
1 2 3 4 5 6 7 8
ON
OFF
ON
8
1
+5V
+12V
N/O
N/C
N/O N/O
N/C N/C
SET RELAY CONTACTS
= N/O = N/C
LOCK
DOOR
OPER.
FORCED
/ DHO
RELAY LEDS TURN
ON ACTIVATION
RED
DOOR OPERATOR OUTPUT
ACTIVATED MOMENTARILY WHEN
HANDICAP BUTTON IS DEPRESSED
AFTER LOCK RELAY IS ACTIVATED.
FORCED ENTRY/DHO OUTPUT
ACTIVATED ON FORCED ENTRY AND/OR
DHO ALARM AS CONFIGURED IN SOFTWARE
N/O: RELAY CLOSES ON
ACTIVATION
N/C: RELAY OPENS ON
ACTIVATION