SmartLock
®
Controller Page 22 of 26
Installation Manual Nov 2018 • Rev. 3.2
DOOR CONTACT BYPASS SWITCH SETTING
Door Contact Connected: Set switch 8 OFF (LEFT on diagram)
Door Contact Not Connected: Set switch 8 ON (RIGHT on diagram)
NOTE: If door contacts are not installed, but door contacts are enabled on
the control panel via switch 8, unlock schedules will fail to take effect.
WIEGAND
DATA LED
COMMS
LED
+5V
+12V
N/O
N/C
N/O N/O
N/C N/C
LOCK
FORCED
/ DHO
DOOR
OPER.
1 2 3 4 5 6 7 8
ONOFF
IF YOU ARE CONNECTING A DOOR CONTACT
SET DIP SWITCH 8 TO OFF (LEFT)
IF YOU ARE CONNECTING A DOOR CONTACT
SET DIP SWITCH 8 ON (RIGHT)
NOT