Instruction manual C324612 Please keep this instruction manual for future reference
CONNECTION TO THE MAINS SUPPLY
WARNING:
This appliance must be earthed
Check that the power rating of the mains supply is suitable for the maximum power of the
appliance as indicated on the rating label.
The fuse rating for this appliance is 32amp.
The appliance is supplied with a mains lead it should be “Hard wired” as follows:
› The “yellow/green” earth wire, which must be connected to a terminal, and has to be about
10mm longer than the other wire.
› The neutral wire has to be connected to the terminal marked with a letter N.
› The Live wire should only be connected to the terminal marked L.
Mains connection can also be made by fitting a double pole switch with a minimum gap between
the contacts of 3mm, proportionate to the load and complying with the regulations in force.
THE YELLOW/GREEN EARTH WIRE SHOULD NOT BE CONTROLLED BY
THE SWITCH.
When a double pole switch is used for mains supply connection it should be easily accessed, once
the appliance is in position.