11
A: Lower the extraction panel - '0' switch
This serves to close the extraction panel
either completely or in intermediate positions
above 180 mm from the hob. When the
extraction panel is being closed, it will remain
in operation until it reaches 180 mm above
the hob. Below this height, the extraction
function will switch off automatically.
B: Raise the extraction panel,
switch on - Speed 1
This serves to bring the extraction panel up to
a maximum height of 300 mm and to
automatically set the first extraction speed
when the panel reaches a height of 180 mm.
Pressing the button when this height is
reached makes it possible to place the
extraction panel in the required intermediate
positions, up to a maximum of 300 mm,
while leaving the extraction speed of the
motor unchanged.
C: Speed 2 switch
D: Speed 3 switch
E: Speed 4 switch
These serve to set the respective suction
speeds after the extraction panel has reached
180 mm above the hob and to set the height
of the extraction panel to a maximum of
300mm by pressing the same button.
F:
Timer
10 minutes after pressing this button and
setting the function, it serves to stop the
extractor motor and close the carriage. The
set function is signalled by the flashing LEDs
“D” for the set speed. The timer can be
cancelled by press-ing the key again.
Other functions:
Automatic turn off:
After 4 hours of continuous use from the
last function selected, the appliance turns off
and closes automatically.
Grease filters saturation:
After 30 hours of working, the speed
indicators “D” will all flash simultaneously,
signaling the grease filters saturation.
To reset this alarm, hold down the
“TIMER” button for at least 3 seconds,
while the carriage is open.
Downdraft calibration:
Calibration of the downdraft after having
installed it, it is necessary to start the
calibration procedure, which is aimed at
adjusting the extraction strength of the
filtering unit. Connect the product to the
power supply, making sure that it is
conformed to the supply voltage
indicated on the technical data label.
Push the 1 button and the aspiration panel
rises. After it has reached a height of
180mm from the gob, press 0, to stop the
extraction then the 'Timer' and after 2 sec.
the 0 button.
The downdraft will carry out the
calibration of its aspiration panel rising and
retracting for some centimeters. During this
phase, the buttons on the push button
control panel flash. At the end of the
calibration, the aspiration panel return to
the previous position and the buttons stop
flashing. Wait until the aspiration panel
stops moving before re-activating the
extraction.
How the downdraft
extractor works
WARNING
This operation has to be carried out by a
specialised technician.