Please keep this instruction manual for future reference
SAFETY INSTRUCTIONS FOR KITCHEN UNIT FITTERS:
Veneers, adhesives and plastic surfaces of surrounding furniture must be temperature
resistant (>75°C). If the veneers and surfaces are not sufficiently heat resistant they may
become deformed.
Ensure that all live connections are safely insulated when installing the hob.
Cover Strips between the wall and the worktop behind the hob which are made of solid
wood are permissible as long as minimum clearances in accordance with the installation
diagrams are maintained.
Minimum clearances of the hob cut-out towards the rear are to be maintained in accordance
with the installation diagram.
For installation directly next to a tall cupboard, a safety distance of at least 50mm must be
ensured. The side surface of the tall cupboard should be fitted with heat resistant material.
Due to working requirements, however, the distance should be at least 300mm.
The packaging materials (plastic foil, polystyrene, nails etc.) must be kept out of reach of
children as these parts are potentially dangerous. Small parts can be swallowed and there is
a danger of plastic sheeting causing suffocation.
VENTILATION:
The induction hob is fitted with a fan that switches on and off automatically. If the
temperature produced by the electronic device exceeds a certain level, the fan turns on at a
low speed. In case the induction hob is being used intensively, the fan switches to a higher
speed. Once the electronics are cooled sufficiently, the fan reduces the speed and switches
off automatically.
Clearance between the induction hob and kitchen furniture or built-in units must provide for
sufficient ventilation of the induction hob.
If the power level of a cooking zone is automatically raised or lowered (see section on
thermal cut-off device) it is likely that the cooling system does not cool sufficiently. In this
case we recommend that the back wall of the bottom kitchen unit in the area of the worktop
cut-out be opened and that the front transverse strip of the unit be removed over the entire
width of the appliance in order to promote the circulation of air.
min. 5 mm
In order to better ventilate the
hob, an air gap of 5mm should
be left at the front.