EasyManua.ls Logo

Carbolite 201 - User Manual

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating Instructions
Temperature Controller
type 201
(APPLICABLE WHEN ALARM FEATURE IS IN USE)
CONTENTS
section page
1 Description 1
2 Basic Operating Instructions 3
3 Overtemperature Option 5
4 Altering the Power Limit 5
5 User Calibration 6
6 Navigation Diagrams 7
See also the main manual for the furnace, oven or other
product to which the controller is fitted.
1
MC07 – 1.04
Question and Answer IconNeed help?

Do you have a question about the Carbolite 201 and is the answer not in the manual?

Summary

201 Controller Description

Key Features of the 201 Controller

Highlights ease of use, ramp-to-setpoint, and alarm output functionality.

Overtemperature Controller Functionality

Details the optional overtemperature controller's features like easy setting and latching alarms.

Furnace or Oven Control Integration

Powering the Controller

Explains power requirements and Instrument switch for controller operation.

Navigating the Controller Interface

Describes Page, Scroll, Down, and Up keys for operation and navigation.

Basic Controller Operations

Altering the Setpoint

Procedure for changing the target temperature using the Down and Up keys.

Advanced Controller Operations

Stopping and Starting Control

Method to stop and start the controller without altering the setpoint.

Altering the Ramp Rate

Guidance on setting a ramp rate to limit heating or cooling speed.

Overtemperature Option Management

Identifying the Overtemperature Option

How to identify if the overtemperature option is fitted on the controller panel.

Overtemperature Alarm Handling

Describes alarm light changes and reset procedure for overtemperature conditions.

Power Limit Adjustment

Power Limit Overview and Purpose

Explains the power limit parameter OP.Hi and its use for compensation or control.

Procedure for Altering Power Limit

Step-by-step guide to changing the OP.Hi parameter, including cautions.

Power Limit for Low Temperature Control

Guidance on reducing power limit for improved stability at low temperatures.

User Calibration Procedure

Accessing and Enabling User Calibration

Steps to access user calibration settings, including password entry and parameter selection.

Setting Calibration Points and Offsets

Details on entering low/high temperature points and their corresponding offsets.

Navigation Diagrams - Main Controller

Navigation Diagrams - Overtemperature Controller

Carbolite 201 Specifications

General IconGeneral
Resolution1°C
Control TypePID
Display Resolution1°C
Temperature RangeUp to 1200°C
Sensor TypeK-type thermocouple
Cooling RateDependent on furnace model
Power Supply50/60Hz

Related product manuals