Page 19
Menu c
S
ET OFFSET
AUTOMATIC LEARNED FORCE LIMITATION
IN
SLOW
SPEED
1. LED F blinks and all others are illuminated.
2. Use & or / to change offset in increments of 1/15 of the maximum.
minimum offset: 1/15
maximum offset: 15/15
3. Press % to store and to finish setting up the learned force settings.
The LEDs will automatically turn off starting at LED 8 and ending at LED 1.
Operator is now in operational (normal) mode (recognizable by illuminated LED I) and
possible LED W (door fully open) or LED R (door fully closed).
Your operator allows the connection of an external signal light provided the optional external light
relay kit is connected and the automatic closing function is activated.
Signal lights can be programmed to be: - constant illuminated signal light
- blinking signal light
M
ENU OVERVIEW:
1 Set timed security cut-out
2 Set external signal lights
3 Programming lighting
4 Programming external light relay kit
T
O PROGRAM THE EXTERNAL LIGHT:
1. From the normal operating mode, press %, & and / simultaneously for more than 10
seconds until LED C blinks rapidly and all others are illuminated
2. Continue to press % and use & or / until LED B blinks rapidly
3. Release %
Menu a
S
ET TIMED SECURITY CUT-OUT (MAX TRAVEL TIME)
1. LED A blinks and all others are illuminated.
2. Use & or / to change value
minimum phase: 30 seconds
maximum phase: 240 seconds
3. Press % to store and go to Menu b
IQ
UW
ZE
TR
240
seconds
KQ
UW
ZE
TR
220
seconds
8Q
UW
ZE
TR
210
seconds
8Q
JW
ZE
TR
200
seconds
8Q
7W
ZE
TR
190
seconds
8Q
7W
HE
TR
180
seconds
8Q
7W
6E
TR
160
seconds
8Q
7W
6E
GR
140
seconds
8Q
7W
6E
5R
120
seconds
8Q
7W
6E
5F
100
seconds
8Q
7W
6E
54
80
seconds
8Q
7W
6D
54
65
seconds
8Q
7W
63
54
55
seconds
8Q
7S
63
54
50
seconds
8Q
72
63
54
40
seconds
8A
72
63
54
30
seconds
CONTROL EXTERNAL LIGHT
IQ
UW
ZE
TR
15/15
KQ
UW
ZE
TR
14/15
8Q
UW
ZE
TR
13/15
8Q
JW
ZE
TR
12/15
8Q
7W
ZE
TR
11/15
8Q
7W
HE
TR
10/15
8Q
7W
6E
TR
9/15
8Q
7W
6E
GR
8/15
8Q
7W
6E
5R
7/15
8Q
7W
6E
5F
6/15
8Q
7W
6E
54
5/15
8Q
7W
6D
54
4/15
8Q
7W
63
54
3/15
8Q
7S
63
54
2/15
8Q
72
63
54
1/15
8A
72
63
54
deakti-
vated