8 Specications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/11/2014
Motor Controllers AC Variable Frequency Drives Type Variex
3
RVLF
3.3.1. Product Specifications
3.3. Specifications
Model: RVLF 340075 340150 340220
Horse power (HP) 1 2 3
Suitable motor capacity (KW) 0.75 1.5 2.2
Rated output current (A) 2.3 3.8 5.2
Rated capacity (KVA) 1.7 2.9 4.0
Input voltage range (V) Three Phase: 380~480V, 50/60HZ
Allowable voltage uctuation +10% / -15%
Output voltage range (V) Three phase 0~480V
Input current (A)
4.2 5.6 7.3
Allowable momentary power loss time (S)
2.0 2.0 2.0
Enclosure IP20
400V Class: Three phase. F: Standards for built-in lter
200V Class: Single phase. F: Standards for built-in lter
Model: RVLF 120020 120040 120075 120150 120220
Horse power (HP) 0.25 0.5 1 2 3
Suitable motor capacity (KW) 0.2 0.4 0.75 1.5 2.2
Rated output current (A) 1.8 2.6 4.3 7.5 10.5
Rated capacity (KVA) 0.68 1.00 1.65 2.90 4.00
Input voltage range (V) Single Phase: 200~240V, 50/60HZ
Allowable voltage uctuation +10% / -15%
Output voltage range (V) Three phase 0~240V
Input current (A) 4.9 7.2 11 15.5 21
Allowable momentary power loss time (S)
1.0 1.0 1.0 2.0 2.0
Enclosure IP20