33 62-11646
U
NIT
D
ATA
- C
ONTINUED
Refer to the following table for additional information on Unit Data.
DATA DEFINITION
FUEL LEVEL % of fuel in tank. (This is only displayed when
an optional fuel level sensor is installed and
Configured ON)
BATTERY Battery voltage. If “OK” is displayed, this indi-
cates battery voltage is sufficient to allow a
Start-Stop Off Cycle
AMP DRAW Battery charging or discharging amps
ENGINE COOLANT
TEMP
Engine coolant temperature
AMBIENT AIR TEMP Ambient (air entering condenser) air
temperature
RETURN AIR TEMP Return (air entering evaporator) temperature
SUPPLY AIR TEMP Supply (air leaving evaporator) temperature
DELTA-T Supply air temperature minus return air
temperature (a negative value indicates
cooling and a positive value indicates
heating)
DEFROST TERM TEMP Defrost termination temperature
REMOTE SENSOR 1
(or 2 or 3)
This is the temperature at the indicated
remote Temperature Sensor. (These
sensors are optional, and may not be
applicable to this unit.)
SUCTION PRESSURE Compressor suction pressure
UNIT AC CURRENT #1 A/C voltage current draw on circuit #1