Start-Up
Procedures
CE
UA
Le:
FIRE
OR
EXPLOSION
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury,
death,
and/or
property
damage.
.
Never
purge
a
gas
line
into
a
combustion
chamber.
Never
Q)
test
for
gas
leaks
with
an
open
flame.
Use
a
commercially
available
soap
solution
made
specifically
for
the
detection
|
of
leaks
to
check
all
connections.
A
fire
or
explosion
may
\
BURNER
result
causing
property
damage,
personal
injury
or
loss
of
i
|
ORIFICE
life.
posose
4
WARNING
ELECTRICAL
SHOCK
HAZARD
Failure
to
follow
this
warning
could
result
in
personal
injury,
or
death.
Fig.
50
-
Orifice
Hole
58CV
Blower
access
door
switch
opens
115-v
power
to
control.
No
component
operation
can
occur
unless
switch
is
closed.
Caution
must
be
taken
when
manually
closing
this
switch
for
service
purposes.
THERMOSTAT
SUBBASE
:
7
:
TERMINALS
WITH
1.
Purge
gas
lines
after
all
connections
have
been
made.
THERMOSTAT
REMOVED
2.
Check
gas
lines
for
leaks.
3
(ANITICIPATOR,
CLOCK,
ETC.,
MUST
BE
OUT
OF
CIRCUIT,)
.
To
Begin
Component
Self-Test:
Remove
Blower
Access
Door.
Disconnect
the
thermostat
HOOK-AROUND
R
lead
from
furnace
control
board.
Manually
close
blower
AMMETER
door
switch.
Turn
Setup
DIP
switch
SW1-6
ON.
(See
Fig.
26,
53
and
Table
10.)
NOTE:
The
furnace
control
allows
ail
components,
except
the
gas
valve,
to
be
run
for
short
period
of
time.
This
feature
helps
diagnose
a
system
problem
in
case
of
a
component
failure.
Component
test
feature
will
not
operate
if
any
thermostat
signal
is
present
at
the
control.
Refer
to
service
label
attached
to
furnace
or
See
Fig.
52.
Component
test
sequence
is
as
follows:
a.
Inducer
motor
starts
on
high-speed
and
continues
to
run
until
Step
d.
of
component
test
sequence.
b.
Hot
surface
igniter
is
energized
for
15
sec.,
then
off.
N
c.
Blower
motor
operates
for
15
sec.
EROM
UNIT
24-V
d.
Inducer
motor
goes
to
low-speed
for
10
sec.,
then
CONTROL
TERMINALS
stops.
e.
After
component
test
is
completed,
one
or
more
status
codes
(11, 25,
or
41)
will
flash.
See
component
test
section
of
service
label
(Fig.
52)
in
furnace
for
explan-
ation
of
status
codes.
EXAMPLE:
5:0:
AMPS
ON
AMMETER
_
_
0.5
AMPS
FOR
THERMOSTAT
4OTURNS
AROUND
JAWS
~
ANTICIPATOR
SETTING
Ag6316
Fig.
51
-
Amp. Draw
Check
with
Ammeter
NOTE:
To
repeat
component
test,
turn
setup
switch
SW1-6
OFF,
then
back
ON.
4.
Turn
setup
DIP
switch
SW1-6
OFF.
Reconnect
R
lead
to
furnace
control
board,
release
blower
door
switch
and
re-
install
blower
access
door.
5.
Operate
furnace
per
instruction
on
inner
door.
6.
Verify
furnace
shut
down
by
lowering
thermostat
setting
below
room
temperature.
7.
Verity
furnace
restarts
by
raising
thermostat
setting
above
room
temperature.