38MHRC: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
22
Indoor Fan Running Rules:
When the compressor is on, the user can set the indoor fan to either
HIGH/MED/LOW/AUTO/MUTE. When the indoor unit coil
temperature is low, the anti-cold air function starts and the indoor fan
motor runs at the low speed. The speed can not be changed.
When the temperature is lower than the setting value, the indoor fan
motor stops. When the indoor temperature reaches the setting
temperature, the compressor stops, the indoor fan motor runs at the
minimum speed or setting speed. The anti-cold air function is valid. The
indoor fan is controlled as shown in Fig. 25.
A210476
Fig. 25 —Indoor Fan Running Rules
Auto fan action in the HEATING mode.
A210477
Fig. 26 —Auto Fan Action in HEATING Mode