38Y CC (50 Hz)
10 SEER Heat Pump
Export Model
S i z e s 1 8 --- 6 0
1---1/2to5NominalTons(7To17.5kW)
Product Data
The 38YCC Outdoor Section of Split-- System Heat Pumps is
designed for quiet, reliable heating during the winter and cooling
during the summer. With EER ratings up to 9.0, this heat pump
system provides economy of operation through energy
conservation when used with components designated by Carrier.
The 38YCC recovers heat for indoor comfort from outdoor air
during the heating season and, by automatically reversing the
refrigerant system, removes indoor heat and excess humidity
during the cooling season.
FEATURES AND BENEFITS
Electrical Range
Single-- phase units are available in sizes 018, 024, and 036 in 230v
50 Hz. Three-- phase units are available in sizes 036, 048, and 060
in 400v 50 Hz.
Wide Range of Sizes
The 38YCC is available in nominal sizes 018, 024, 036, 048 and
060 to meet the needs of residential and light commercial
applications.
Unit Design
All units are equipped with totally enclosed fan motors for greater
reliability under adverse weather conditions. The large,
wrap--around coil uses copper tube and enhanced epoxy coated
aluminum fin and is designed for optimum heat transfer and
corrosion protection during heating and cooling. The vertical air
discharge carries the sound and air up and away from adjacent
patio areas and foliage. Coil can be cleaned with a common garden
hose.
Weather--Protective Cabinet
A weather protective cabinet of pre--painted steel is protected
underneath by a zinc galvanized coating for a finish that will last
for many years. All screws on cabinet exterior are coated for a
long--lasting, rust--resistant, quality appearance.
Compressor
Designed specifically for heat pump duty, with energy efficiency
during heating and cooling operation. The compressor is
hermetically sealed against contamination to assure long life and
dependable performance, internally sprung (units with
reciprocating compressor), and externally mounted on rubber
isolators for quiet operation. For improved serviceability, all
models are equipped with a compressor terminal plug.
Compressor Protection
Each compressor is protected with internal temperature-- and
current--sensitive overloads.
Reliable standard components
Includes a suction--tube accumulator that reduces the amount of
liquid refrigerant that reaches the compressor; a high pressure
switch to prevent excessive pressure build --up; a low--pressure
switch to stop the compressor if refrigerant charge is lost; a
crankcase heater to keep compressor oil warm and free of
refrigerant for maximum lubricity; an internal compressor relief
valve for high--pressure protection; and 5--minute compressor
delay.
3--phase monitor board (scroll compressor models)
Control board that monitors the electrical phase and prevents
compressor operation if wired incorrectly. Standard on 048 and
060 3 phase equipment.