Carrier 38YCC Series - Operating Your Heat Pump; Thermostat Controls; Cooling Cycle; Heating Cycle

Carrier 38YCC Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
ELECTRICAL DATA
OUTDOOR
UNIT
V/PH
OPER VOLTS* COMPRESSOR
FAN
FLA
MCA
MIN
WIRE
SIZE**
60˚C/
75˚C
MAX
LENGTH
(Ft)‡
60˚C/
75˚C
MAX
LENGTH
(m)‡
60˚C/ 75˚C
MAX FUSE†
OR CKT
BKR AMPS
Max Min LRA RLA
018--- 7A
230---1 253 207
55.0 8.8 0.52 11.5 14/14 66/62 20.1/18.9 20
024--- 7A 68.0 11.5 0.52 14.9 14/14 55/39 16.7/11.9 25
036--- 7A 94.0 16.5 1.6 22.2 12/12 65/47 19.8/14.3 35
036--- 9A
400---3 440 360
42.0 6.4 0.7 8.7 14/14 260/247 79.2/75.3 15
048--- 9A 63.0 7.9 0.7 10.7 14/14 165/157 50.3/47.9 15
060--- 9A 74.0 9.0 0.7 11.9 14/14 165/157 50.3/47.9 20
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
{ If wire is applied at ambient greater than 30˚C, consult Table 310---16 of the NEC (ANSI/NFPA 70) . The ampacity of nonmetallic---sheathed cable (NM), trade
name ROMEX , shall be that of 60˚C conductors, per the NEC (ANSI/NFPA 70) Article 336 ---26. If other than uncoated (non ---plated), 60 or 75˚C insulation, cop-
per wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
} Length shown is as measured 1 way along wire path between the unit and service panel for a voltage drop n ot to exceed 2%.
* * T i m e --- d e l a y f u s e .
FLA --- Fu l l L o a d A mp s
LRA --- L o ck e d R o to r A m ps
MCA --- Minimum Circuit Amps
RLA --- RatedLoadAmps
NOTES:
1. Control circuit is 24v on all units and requires external power source.
2. Copper wire must be used from service disconnect to unit.
3. All motors/compressors contain internal overload protection.
METERING DEVICE
UNIT SIZE---SERIES OUTDOOR PISTON INDOOR PISTON*
REQUIRED SUB---COOLING
WITH TXV EXAPNSION
DEVICE
_F(_C)
018---7A 40 57 12 (6.7)
024---7A 49 63 12 (6.7)
036---7A 61 73 9 (5.0)
036---9A 61 73 11 (6.1)
048---9A 73 90 9 (5.0)
060---9A 76 96 10 (5.6)
* Piston listed is for any approved non ---capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil.
A--WEIGHTED SOUND POWER (dB)
UNIT SIZE
SOUND
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dB, Without Tone Adjustment)
125 250 500 1000 2000 4000 8000
018 76 49.5 58.0 66.5 69.5 67.0 66.5 59.5
024 76 54.0 63.0 63.5 68.0 66.0 67.5 64.5
036 77 56.5 65.5 68.5 70.5 69.0 67.5 62.5
048 77 56.0 59.5 67.5 72.5 70.0 69.5 66.0
060 77 55.5 62.5 70.0 73.0 70.5 68.5 64.5