17
For 9K, 12K models:
Compressor
on
off
on
on
on
off
off
off
4-way valve
Outdoor fan
Indoor fan
Indoor fan breeze(10s)
xx
10s
30s
10s
Defrost Cycle
(no longer than 10 min.)
xx=60s for 9k & 12k models
For 18K, 26K models:
XX=60 for 18k model, XX=90 for 26K, 30K models
 
Compressor
on
off
on
on
on
off
off
off
4-way valve
Outdoor fan
Indoor fan
Indoor fan breeze(10s)
xx
Defrost Cycle
(no longer than 10 min.)
30s
10s
10s
AUTO MODE
In the Auto mode, the temperature can be set to values between
62~86F (17~30). In this mode, the machine will choose
cooling, heating or fan- only mode according to ΔT.
NOTE: ΔT =T1- Ts, where T1 represents the indoor room
temperature and Ts represents the set temperature.
ΔT=T1- Ts
Running mode
ΔT>33F Cooling
-1<ΔT≤33F
Fan- only
ΔT≤- 30F
Heating
Indoorfa n will run at an automa t ic fan spee d f oreach running mode. The
louver will also operate depending in re levant mode taking place.
If the machine switches mode between heating and cooling, the
compressor stops for 15 minutes and then chooses a mode
according to ΔT.
If a new set temperature is commanded, the system chooses a
running mode according to ΔT.
FORCED OPERATION FUNCTION
When the machine is off, pressing the manual button carries the
machine to forced auto mode. Press the button once again, within
5 seconds, the machine turns to forced cooling mode. In forced
auto, forced cooling or any other operation mode, press the
manual button to turn the machine off. When in this mode, all
general protections and remote control functions are available.
Forced cooling
mode:
The compressor runs at F2 frequency and indoor fan runs as
breeze. After running for 30 minutes, the machine turns to auto
mode with a 75_F(24_C) set temperature.
Forced auto
mode:
The action of forced auto mode is the same as normal auto mode
with a 75_F(24_C) set temperature.
TIMER FUNCTION
Timing range is 24 hours.
The timer function will not change the system’s current operation
mode. The setting time is relative time.
Timer
on
The machine turns on automatically when reaching the set time.
Timer
off
The machine turns off automatically when reaching the setting time.
Timer
on/off
The machine turns on automatically when reaching the set “on” time,
and then turn off automatically when reaching the set “off” time.
SLEEP MODE FUNCTION
Operation time in sleep mode is 7 hours. After 7 hours the system
turns off. Operation process in sleep mode is as follow:
When in cooling mode, the set temperature rises 1.8_F(1_C) (up
to a maximum 86_F(30_C)) every one hour. Two hours later the
set temperature stops rising and indoor fan is fixed at low speed.
Time (hour)12
2.0
°
F(-16.7 
°C
)
2.0
°
F(-16.7 
°
C)
°
Set point
Fig. 23 – Sleep Mode - Cooling
When in heating mode, the set temperature decreases 2.0_F (- 16.7_C)
(dow n to a minimum 62_F(17_C)) eve r y one hour. Two hours later
the set te m perature stops ri sing and indoor fa n is fi xed at low speed.
NOTE: Anti-cold wind function has the priority.
Time (hour)12
2.0
°
F(-16.7 
°C
)
2.0
°
F(-16.7 
°
C)
°
Set point
Fig. 24 – Sleep Mode - Heating
When the user uses timer off function in sleep mode (or sleep
function in timer off mode), if the timing is less than 7 hours, sleep
function will be cancelled when reaching the setting time. If the
timing is more than 7 hours, the machine will not stop until it
reaches the set time in sleep mode.