3
STANDARD FEATURES AND ACCESSORIES
Table 1—Standard Features and Accessories
Ease Of Installation
Indoor and Outdoor Compact Size S
Outdoor Unit Wall Mounting Kit A
Outdoor Unit Stacking Kit A
Indoor Mounting Bracket S
Comfort Features
Convertible Under Ceiling -- Floor Console S
Microprocessor Controls S
Wireless Remote Control S
Automatic Air Sweep S
Air Direction Control S
Auto Restart Function S
Cold Blow Protection On Heat Pumps S
Turbo Mode S
Silence Mode S
Follow Me S
Energy Saving Features
Sleep Mo de S
Stop/Start Timer S
46 ° F Heating Mode (Heating Setback) S
Safety And Reliability
3 Minute Time Delay For Compressor S
Over Current Protection For Compressor S
Crankcase Heater (stand ar d on sizes 30 and 36 Heat Pump) A
Indoor Coil Freeze Protection S
Indoor Coil High Temperature Protection On Heat Pumps S
Condenser High Temperature Protection On Heat Pumps S
Accumu lator On Heat Pumps S
Ease Of Service And Maintenance
Cleanable Filters S
Diagnostics S
Liquid Line Pressure Taps S
Suction And Discharge Pressure Taps S
Application Flexibility
Low Ambient Controls ( --20F) (--28.9C) A
3--Phase on sizes 34 & 54 (AC) and 36 & 48 (HP) S
Wind Baffles A
Condensate Pumps A
Wired Controls A
Legend
SStandard
A Accessory
Table 2—Optional Accessories
Ordering No. Descriptions For Models
KSACN0101AAA Wired Remote Control All Sizes
53DS--900-- ----118 Condensate Pump (230v) All Sizes
KSALA0801AAA
Low Ambient Control (for
cooling -- 20F)
24AHA4/25HHA4 (208/230V)
KSALA0901AAA
Low Ambient Control (for
cooling -- 20F)
24AHA4 (460V--3)
KAACH1401AAA Crankcase Heater 24AHA4 Sizes 18--36 (208/230V)
KAACH1501AAA Crankcase Heater 24AHA4 Size 36 (460V--3)
KAACH1201AAA Crankcase Heater 24AHA4 Size 48 (208/230V)
KAACH1901AAA Crankcase Heater 24AHA4/25HHA4 Size 48 (460V--3)
KAACH1601AAA Crankcase Heater 25HHA4 Size 48 (208/230V)
KAAWS0101AAA
Winter Start Kit (for low
ambient on cooling only
systems)
24AHA4 All Sizes
KHAIR0201AAA
Isolation Relay (Required
when using Low Ambient
cooling with HP)
25HHA4 All Sizes
KSAHS1501AAA
Hard Start Kit (Capacitor
& Relay)
24AHA4/25HHA4 (208/230V--1)
53DS--900-- ----087 Wind Baffle 24AHA4 Sizes 18 & 24
53DS--900-- ----071 Wind Baffle
24AHA4 Sizes 30--48 / 25HHA4 Sizes
30 & 36
53DS--900-- ----088 Wind Baffle 25HHA4 Size 48
53DS--900-- ----075 Stacking Kit 24AHA4 Sizes 18, 24
53DS--900-- ----076 Stacking Kit 24AHA4 Sizes 30 -- 48
53DS--900-- ----077 Wall Mount Kit 24AHA4 Sizes 18, 24
53DS--900-- ----078 Wall Mount Kit 24AHA4/25HHA4 Sizes 30 -- 48
KAALS0201LLS
Liquid Line Solenoid for
Cooling Only
24AHA4 All Sizes -- Required for Long
Line Applications
KHALS0401LLS
Liquid Line Solenoid for
Heat Pump
25HHA4 All Sizes -- Required for Long
Line Applications
INDOOR UNIT ACCESSORIES
Condensate Pump
A07892
Fig. 1 Condensate Pump Accessory
On ductless fan coils, the condensate pump has a lift capability of
12 ft. (3.6 m) on the discharge side with the pump mounted in the
fan coil or 6 ft. (1.8 m) on the suction side if the pump is remote
mounted. The pump is recommended when adequate drain line
pitch cannot be provided, or when the condensate must move up to
exit.
Wired Remote Controller
For applications where the use of wireless remote control is not
desired, the MK units can be controlled by means of a wired
wall-- mounted control with an LCD display.
Fig. 2 Wall Mounted Contro l with LCD Display