Model
Indoor unit
40TGV
0251UP 0301UP
Outdoor unit
38TGV
0251A1 0301A1
Cooling capacity (kW)
7.40 8.80
Power supply
Indoor unit
1 phase 220V 50Hz (Supplied by outdoor unit)
Electrical
characteristics
Cooling
Running current (A)
9.25
11.80
Power consumption (kW)
1.92 2.45
Power factor (%)
94 94
EER
3.85 3.59
Maximum current (A)
14.50 18.00
Appearance
Main unit Zinc hot dipping steel plate
Ceiling panel(Sold separately) RBC-U31PGX(W)-T
Outer dimension
Main unit
Height (mm) 256 256
Width (mm) 840 840
Depth (mm) 840 840
Ceiling panel
(Sold separately)
Height (mm) 30 30
Width (mm) 950 950
Depth (mm) 950 950
Total weight
Main unit (kg) 20 20
Ceiling panel(Sold separately) (kg) 4.2 4.2
Heat exchanger Finned tube
Fan unit
Fan Turbo fan
Standard air flow
H/M/L
(m3/hr.)
1230/960/810 1820/1360/1080
Motor (W)
60 150
Air filter Standard filter attached (Long life filter)
Controller
CARR-AMT32E (optional), WC-L19SE (provided)
Sound pressure level H/M/L (dB·A)
35/31/28 43/39/37
Sound power level H/M/L (dB·A)
50/46/43 58/54/52
Connecting pipe
Gas side (mm)
15.9
15.9
Liquid side (mm)
9.5
9.5
Drain port (mm) VP25
Outdoor unit
1 phase 220V 50Hz