Model
Indoor unit 40TGV
0401UP 0481UP
Outdoor unit
38TGV
0401A3 0481A3
Cooling capacity (kW)
11.80 14.10
Power supply
Indoor unit
1 phase 220V 50Hz (Supplied by outdoor unit)
Electrical
characteristics
Cooling
Running current (A)
5.50
7.70
Power consumption (kW)
3.33 4.70
Power factor (%)
92 93
EER
3.54 3.00
Maximum current (A)
14.10 14.10
Appearance
Main unit Zinc hot dipping steel plate
Ceiling panel(Sold separately) RBC-U31PGX(W)-T
Outer dimension
Main unit
Height (mm)
319 319
Width (mm) 840 840
Depth (mm) 840 840
Ceiling panel
(Sold separately)
Height (mm) 30 30
Width (mm) 950 950
Depth (mm) 950 950
Total weight
Main unit (kg)
24 24
Ceiling panel(Sold separately) (kg) 4.2 4.2
Heat exchanger Finned tube
Fan unit
Fan Turbo fan
Standard air flow
H/M/L
(m3/hr.)
2130/1440/1230 2130/1500/1260
Motor (W)
130 130
Air filter Standard filter attached (Long life filter)
Controller
CARR-AMT32E (optional), WC-L19SE (provided)
Sound pressure level H/M/L (dB·A)
47/43/38 47/44/39
Sound power level H/M/L (dB·A)
62/58/53 62/59/54
Connecting pipe
Gas side (mm)
15.9
15.9
Liquid side (mm)
9.5
9.5
Drain port (mm) VP25
0601UP
0601A3
17.8
9.60
5.93
94
3.00
14.10
319
840
840
30
950
950
24
4.2
2200/1820/1500
130
48/45/43
63/60/58
19.0
9.5
Outdoor unit
3 phase 380V 50Hz