APPENDIX A — BLOCK-OUT CONSTRUCTION (cont.)
Table C — STANDARD 88-IN. CABINET (Four-Pipe
42S Units)
* Not recommended for Siamese Back-to-Back Installation.
† Use 16-in. block-out length for risers up to 1
1
/
2
-in. in diameter. Use
17-in. block-out length for risers up to 2
1
/
2
-in. in diameter. Since the
cabinet is 17-in. wide, it may be necessary to cover the exposed
block-out if the cabinet is not centered.
** This block-out length is for risers up to 1
1
/
2
-in. in diameter. Add 1-in.
to the block-out length for risers up to 2
1
/
2
-in. in diameter. Both block-
out lengths are greater than the cabinet width. It will be necessary to
cover the exposed block-out at the side(s) of the cabinet.
†† This block-out length is for risers up to 1
1
/
2
-in. in diameter. Add 1-in.
to block-out length for risers up to 2
1
/
2
-in. in diameter.
*** Use 17-in. block-out length for risers up to 1
1
/
2
-in. in diameter. Since
the cabinet is 17-in. wide, it may be necessary to cover the exposed
block-out if the cabinet is not centered. Use 18-in. block-out length for
risers up to 2
1
/
2
-in. in diameter. It will be necessary to cover the
exposed block-out at the side(s) of the cabinet.
NOTES:
1. CLEAR HEIGHT is the dimension from the floor to ceiling (See
Fig. A of this appendix).
2. The above charts allow 1-in. tolerance in clear height to allow for
variance in floor-to-floor dimensions.
3. Consult factory for applications with 3-in. and 4-in. risers and insu-
lations exceeding
3
/
4
-inch.
4. See Figure B for 42SJ unit and piping arrangements.
Table D — SHORT 79-IN. CABINET (Four-Pipe
42S Units)
* Not recommended for Siamese Back-to-Back Installation.
† Use 16-in. block-out length for risers up to 1
1
/
2
-in. in diameter. Use
17-in. block-out length for risers up to 2
1
/
2
-in. in diameter. Since the
cabinet is 17-in. wide, it may be necessary to cover the exposed
block-out if the cabinet is not centered.
** This block-out length is for risers up to 1
1
/
2
-in. in diameter. Add 1-in.
to the block-out length for risers up to 2
1
/
2
-in. in diameter. Both block-
out lengths are greater than the cabinet width. It will be necessary to
cover the exposed block-out at the side(s) of the cabinet.
†† This block-out length is for risers up to 1
1
/
2
-in. in diameter. Add 1-in.
to block-out length for risers up to 2
1
/
2
-in. in diameter.
*** Use 17-in. block-out length for risers up to 1
1
/
2
-in. in diameter. Since
the cabinet is 17-in. wide, it may be necessary to cover the exposed
block-out if the cabinet is not centered. Use 18-in. block-out length for
risers up to 2
1
/
2
-in. in diameter. It will be necessary to cover the
exposed block-out at the side(s) of the cabinet.
NOTES:
1. CLEAR HEIGHT is the dimension from the floor to ceiling (See
Fig. A of this appendix).
2. The above charts allow 1-in. tolerance in clear height to allow for
variance in floor-to-floor dimensions.
3. Consult factory for applications with 3-in. and 4-in. risers and insu-
lations exceeding
3
/
4
-inch.
4. See Figure B for 42SJ unit and piping arrangements.
UNIT SIZE
CLEAR
HEIGHT
(in.)
BLOCK-OUT CONSTRUCTION SIZE
TYPE OF INSTALLATION
TYPE 1 TYPE 2 TYPE 3*
W x L (in.) W x L (in.) W x L (in.)
Single Unit and Siamese Back-to-Back
03, 04
96 5
7
/
8
x 16
†
5
1
/
8
x 16
†
5 x 18**
95 6
1
/
4
x 16
†
5
3
/
8
x 16
†
5 x 18
1
/
4
**
94 6
5
/
8
x 16
†
5
5
/
8
x 16
†
5 x 18
5
/
8
**
93 7 x 16
†
NR
92 7
1
/
2
x 16
†
06, 08
96 6
1
/
4
x 18
5
3
/
8
x 18
5 x 18
††
95 6
3
/
4
x 18 5 x 18
1
/
4
††
94 7
1
/
8
x 18
NR
5 x 18
5
/
8
††
93 7
5
/
8
x 18 NR
10, 12
96 7
1
/
2
x 22 5
1
/
8
x 22
5 x 22
95 7
1
/
2
x 22
NR
94 8 x 22 NR
42SJ Back-to-Back
03, 04
96
Not recommended for
standard 42SJ. For Sia-
mese 42SJ use Single
unit guidelines.
5 x 18
95 5 x 18
1
/
4
94 5 x 18
5
/
8
06, 08
96 5 x 18
95 5 x 18
1
/
4
94 5 x 18
5
/
8
10, 12
96
5 x 22
95
UNIT SIZE
CLEAR
HEIGHT
(in.)
BLOCK-OUT CONSTRUCTION SIZE
TYPE OF INSTALLATION
TYPE 1 TYPE 2 TYPE 3*
W x L (in.) W x L (in.) W x L (in.)
Single Unit and Siamese Back-to-Back
03, 04
91 4
1
/
8
x 16
†
4
1
/
4
x 16
†
5 x 17***
90 5 x 16
†
4
1
/
2
x 16
†
89 5
1
/
8
x 16
†
4
5
/
8
x 16
†
5 x 17
1
/
2
**
88 5
1
/
8
x 16
†
5 x 16
†
5 x 17
3
/
4
**
06, 08
91 5 x 18 4
1
/
4
x 18
5 x 18
90 5
3
/
8
x 18 4
1
/
2
x 18
89 5
3
/
4
x 18 4
5
/
8
x 18 5 x 18
1
/
2
88 6
1
/
8
x 18 5 x 18 5 x 18
3
/
4
10, 12
91 5
5
/
8
x 22 4
1
/
4
x 22
5 x 22
90 6 x 22 4
1
/
2
x 22
89 6
1
/
2
x 22 4
5
/
8
x 22
88 7 x 22 5 x 22
42SJ Back-to-Back
03, 04
91
Not recommended for
standard 42SJ. For Sia-
mese 42SJ use Single
unit guidelines.
5 x 17
90
89 5 x 17
1
/
2
88 5 x 17
3
/
4
06, 08
91
5 x 18
90
89 5 x 18
1
/
2
88 5 x 18
3
/
4
10, 12
91
5 x 22
90
89
88