EasyManua.ls Logo

Carrier 48NLT - Page 17

Carrier 48NLT
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
5
Air
Delivery
(Cfm)
at
Indicated
Temperature
Rise
and
Rated
Heating
input
NOMINAL
SIZE
HEATING
UNIT
TEMPERATURE
RISE
fF)
INPUT
(Btuh)
20
25
30
35
40
I
45
50
55
60
65
1
70
75
1
80
NLT018,024,030
40,000
-
!
-
987
846
740
!
658
592
538
493
-
-
-
NHT024;
NMT030
60,000
_
1
1
-
-
-
987
888
808
740
683
!
634
592
1
-
NLT036,042
60,000
-
-
1
1481
1269
1111
987
888
808
740
-
!
-
-
i
NHT030;
NMT036,042
80,000
-
-
-
1316
1185
1077
987
911
846
790
-
NLT048
80,000
^
1
2370
i
1975
1693
1481
1316
1185
1077
-
-
-
!
-
-
NLT060
80,000
2962
2370
'
1975
1693
1481
1316
1185
-
-
-
-
-
-
NET036,042
96,000
-
~
1
-
1777
1580
1422
1292
1185
1096
1015
-
-
NHT036,042;
NMT048
100,000
-
I
2116
1851
1646
1481
1346
1234
1139
-
1
-
-
NMT060
100,000
-
1
""
1
2469
1
2116
1851
1646
1481
1
1346
1234
-
-
-
-
NVT036,042;
NHT048
120,000
-
-
!
-
-
~
1777
I
1616
1481
1367
1269
1185
1111
NHT060
120,000
-
-
2539
2222
1975
1777
1616
1481
1367
-
-
NVT048,060
144,000
-
-
-
2370
2133
i
j
1939
1777
1641
1
1523
1422
-
NOTE:
Dashed
areas
of
the
table
do
not
fall
in
the
approved
temperature
rise
range
of
the
unit
Table
6
~
Superheat
Charging
Table*
OUTDOOR
INDOOR
COIL
ENTERING
AIR
TEMP
(F
wb)
TEMP
(F)
50
52
54
56
58
60
62
i
64
66
68
70
72
74
76
55
9
12
14
17
20
23
26
29
32
35
37
40
42
45
60
7
10
12
15
18
21
24
27
30
33
35
38
40
43
65
-
6
10
13
16
19
21
24
27
30
33
36
38
41
70
-
-
7
10
13
16
19
21
24
27
30
33
36
39
75
-
-
6
9
12
15
18
21
24
28
31
34
37
80
-
-
-
-
5
8
12
15
18
21
25
28
31
35
85
-
~
-
~
8
11
15
19
22
26
30
33
90
-
-
_
i
-
-
-
5
9
13
16
21
24
27
31
95
-
-
-
-
-
6
10
14
18
22
25
29
100
-
-
-
-
-
-
8
12
15
20
23
27
105
-
-
-
-
-
-
-
5
9
13
1
17
22
26
110
-
-
-
-
-
-
-
-
6
11
15
20
25
115
-
-
-
_
1
1
-
-
_ZIJ
-
8
14
18
23
‘Superheat
at
suction
service
valve.
NOTE;
Do
not
attempt
to
charge
system
under
these
conditions;
refrigerant
slugging
may
occur
Table
7
Required
Suction-Tube
Temperature
(F)*
TEMP
(F)
61.5
64.2
67.1
70.0
73.0
1
76.0
!
79.2
82.4
!
85^7
0
35
37
39
41
43
!
45
1
47
49
'
51
2
37
39
41
I
43
45
1
47
49
51
i
53
4
39
41
43
:
45
47
49
51
53
i
55
6
41
43
45
!
47
49
51
53
55
!
57
8
43
45
47
'
49
51
53
55
57
1
59
10
45
47
49
1
51
53
55
57
59
61
12
47
49
51
53
55
57
59
61
63
14
49
51
53
55
57
59
61
63
65
16
51
53
55
57
59
61
63
65
67
16
53
I
55
57
59
61
63
65
67
69
20
55
1
57
59
61
63
65
67
69
71
22
57
1
59
61
63
65
67
69
71
73
24
59
61
63
65
67
69
71
73
75
26
61
63
65
67
69
71
73
75
77
28
63
i
65
67
69
71
73
75
77
79
30
65
67
69
.
71____i
73
75
77
79
81
32
67
69
71
75
77
79
81
83
34
69
71
73
75
!
77
79
81
83
85
36
71
73
75
77
79
81
83
85
87
38
i
73
75
77
79
I
81
83
85
!
87
89
40
'
75
77
79
81
;
83
85
87
'
89
91
‘Temperature
at
suction
service
valve
17