THERMOSTAT
ASSEMBLY
LOW-VOLTAGE
THERMOSTAT
CONNECTIONS
IN
UNIT
CONTROL
BOX
->
Fig.
12
Field
Control
Thermostat
Wiring
Unit
failure
as
a
result
of
operation
on
improper
line
voltage
or
excessive
phase
imbalance
constitutes
abuse
and
may
cause
damage
to
electrical
compo¬
nents.
Such
operation
would
invalidate
any
appli¬
cable
Carrier
warranty.
UNITS
WITH
ELECTRIC
HEAT
When
elec¬
tric
heat
is
installed,
connect
the
field
power
wires
to
terminal
block
located
in
the
single
point
box.
The
single
point
box
is
attached
to
the
corner
post,
directly
below
the
control
box.
DISCONNECTS
A
fused
disconnect
is
required
only
on
units
without
electric
heat.
When
electric
heat
is
installed,
use
a
NEC
disconnect
of
adequate
size.
Provide
fusing
for
disconnect
if
required
by
local
codes.
The
unit
informative
nameplate
and
Table
2
list
electric
heat
fuse
and
wire
amperage.
Field
Control
Wiring
Install
a
Carrier-approved
accessory
thermostat
assembly
according
to
instal¬
lation
instructions
included
with
accessory.
Locate
thermostat
assembly
on
a
solid
wall
in
the
condi¬
tioned
space
to
sense
average
temperature.
THERMOSTAT
WIRES
Use
18
gage
for
0-
to
50-ft
long
wires,
16
gage
for
50-
to
75-ft
wire
lengths.
Route
the
control
wires
thru
hole
provided
in
the
corner
post
(see
Fig.
3
and
4)
and
then
feed
wires
thru
a
raceway
built
into
the
corner
post.
Route
wires
from
the
raceway
into
the
24-v
barrier
located
on
the
left
side
of
the
control
box.
Make
connections
as
shown
in
Fig.
12.
Set
heat
anticipator
settings
as
indicated
below.
Heat
Anticipator
Settings
1st
Stage
9
2nd
Stage
with
2
Heaters
and
2-Stage
Heat
Thermostat*
3
*Applies
only
to
50CD
Settings
may
be
changed
slightly
to
provide
a
greater
degree
of
comfort
for
a
particular
installation.
Refer
to
accessory
remote
control
panel
instruc¬
tions
as
required.
Return
Air
Filters
(50CD008)
Make
sure
correct
filters
are
installed
in
filter
tracks.
See
Table
1.
Do
not
operate
unit
without
return
air
filters.
Outdoor
Air
Inlet
Screens
(50CD008)
Out¬
door
air
inlet
screen(s)
must
be
in
place
before
operating
unit.
Economizer
Section
(50CD008)
Optional
economizer
is
shipped
with
hood
broken
down
in
unit
filter
section.
See
Fig.
13.
Fig.
13
Access
Panel
Location
ASSEMBLY
1.
Remove
protective
polyethylene
cover
from
unit.
See
Fig.
13.
2.
Remove
upper
filter
access
panel
(save
screws).
See
Fig.
13.
3.
Remove
hood
parts
from
unit
evaporator
fan
and
filter
area.
Assemble
hood
top
and
side
plates
as
shown
in
Fig.
14.
Do
not
attach
hood
to
unit
at
this
time.
Put
aside
baffle,
screen
retainer
and
retainer
screw
for
later
assembly.
4.
Determine
if
vent
air
is
required
in
building
to
be
conditioned.
If
so,
check
for
percentage
of
9