DIMENSIONS
2-7/16"
1-1/8"
28-7/8"
(733mm)
25-1/4"
22-9/16"
JUNCTION BOX
LOCATION
7/8" DI A
ACCESSORY
1/2" (13 mm) DIA.
THERMOSTAT WIRE ENTRY
3-15/16" (84mm)
LEFT HAND GAS
ENTRY
33-5/16"
24-7/8"
5-1/2"
7/8" (22mm) DIA.
ACCESSORY
11/16"
21-5/8"
BOTTOM INLE T
1-11/16"
13/16"
11/16"
4-13/16"
AIRFLOW
19"
OUTLE T
13/16"
11/16"
8-9/16"
VENT OUTLE T
5 PLACES (TYP)
3-3/4"
1-3/4" DIA.RIGHT HAND
GAS ENTRY
7/8" DIA. K.O. WIRE ENTRY
SIDE INLE T
14-7/8"
7/8" DIA. ACCESSORY
1-1/4"
1"
22-1/16"
A
D
F
E
(FLUE COLLAR)
5-15/16"
(135mm)
24"
CASING
1-5/16"
1/2" DIA. K.O.THERMOSTAT
WIRE ENTRY
ALTERNAT E
JUNCTION BOX
LOCATIONS (TYP)
26-1/8"
1-1/2"
7-3/4"
9-5/8"
11-1/2"
5-1/2"
(664mm)
(641mm)
(573mm)
(22mm)
(846mm)
(17mm)
(549mm)
610mm
(43mm)
(140mm)
(632mm)
(17mm)
(140mm)
(95mm)
(21mm)
(122mm)
(217mm)
(62mm)
(33mm)
(29mm)
(483mm)
(13mm)
(44mm)
(22mm)
(22mm)
(38mm)
(560mm)
(25mm)
(32mm)
(378mm)
(17mm)
(197mm)
(244mm)
(292mm)
(21mm)
A04037
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
a. For 800 CFM---16---in. (406 mm) round or 14 1/ 2 x 12 ---in. (368 x 305 mm) re ctangle.
b. For 1200 CFM---20 ---in. (508 mm) roun d or 14 1/ 2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22 ---in. (559 mm) roun d or 14 1/ 2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both sideinlets,a
combination of 1 side and the bottom, or the bottom only will en sur e a dequate retur n air openings f or airflow requirements above 1800 CFM.
FURNACE SIZE
A
CABINET
WIDTH
IN (mm)
D
SUPPLY ---AIR
WIDTH
IN (mm)
E
RETURN---AIR
WIDTH
IN (mm)
F
CENTER LINE
TOP AND
BOTTOM FLUE
COLLAR
IN (mm)
FLUE
COLLAR*
IN (mm)
SHIP WT
LB (KG)
FILT ER
MEDIA
CABINET
IN (mm)
045---08 14---3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9---5/16 (237) 4 (102) 104 (47) 16 (406)
045---12 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9 --- 5/16 (237) 4 (102) 107 (48) 16 (406)
070---08 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9 --- 5/16 (237) 4 (102) 111 (50) 16 (406)
070---12 14--- 3/16 (360) 12--- 9/16 (319) 12---11/16 (322) 9 --- 5/16 (237) 4 (102) 115 (52) 16 (406)
070---16 17--- 1/2 (445) 15---7/8 (403) 16--- 1/8 (410) 11--- 9/16 (294) 4 (102) 126 (57) 16 (406)
090---14 17--- 1/2 (445) 15---7/8 (403) 16--- 1/8 (410) 11--- 9/16 (294) 4 (102) 127 (58) 16 (406)
090---16 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13---5/16 (338) 4 (102) 140 (64) 20 (508)
090---20 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13---5/16 (338) 4 (102) 146 (66) 20 (508)
110---12 17--- 1/2 (445) 15---7/8 (403) 16--- 1/8 (410) 11--- 9/16 (294) 4 (102) 135 (61) 16 (406)
110---16 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13---5/16 (338) 4 (102) 146 (66) 20 (508)
110---22 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13---5/16 (338) 4 (102) 152 (69) 20 (508)
135---16 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13---5/16 (338) 4 (102){ 149 (68) 20 (508)
135---22 24--- 1/2 (622) 22---7/8 (581) 23 (584) 15--- 1/16 (383) 4 (102){ 163 (74) 24 (610)
155---20 24--- 1/2 (622) 22---7/8 (581) 23 (584) 15--- 1/16 (383) 4 (102){ 170 (77) 24 (610)
* 5--- in. or 6--- in. (127 or 152 mm) vent connector may be required in some cases.
{ 135 and 155 size furnaces require 5---in. (127 mm) or larger vents. Use a 4 to 5 or 4 to 6---in. (102 to 127 or 102 to 152 mm) vent adapter between furnace and
vent connector.
58CTA/CTX