DUAL FUEL SINGLE-STAGE SINGLE-SPEED DUAL FUEL SINGLE-STAGE TWO-SPEED
THERMOSTAT FURNACE HEAT PUMP THERMOSTAT FURNACE HEAT PUMP
RVS COOLING [_
N/A
HEAT STAGE 2
(FURNACE) [_
HEAT/COOL STAGE t
(COMPRESSOR)
FAN [_
24 VAC HOT [_
24 VAC COMM [_
N/A [_
RVS SENSING [_
CONNEDT,ON_
See notes 1,2, 4,11,12, and 13 on the page following these figures
RVS COOLING
HEAT/COOL STAGE 1
(COMPRESSOR LO)
HEAT STAGE 3 [_
{FURNACE)
HEAT/COOL STAGE 2
(COMPRESSOR HI)
FAN [_
24 VAC HOT [_
24 MAC COMM [_
N/A [_
RVS SENSING [_
%t_ooR_[2_
CONNEOT,ON_
See notes 1 2 3 4- 11 12 and 14- on the page following these figures
A04219
Fig. 30 - Dual Fuel Thermostat with Single-Stage Furnace
and Single-Speed Heat Pump
A04220
Fig. 31 - Dual Fuel Thermostat with Single-Stage Furnace
and Two-Speed Heat Pump
TWO-STAGE SINGLE-STAGE TWO-SPEED
THERMOSTAT FURNACE AIR CONDITIONER
m
See note 2 on the page following these figures.
-Fq I -
...........
I
...........
...........
.[] 1.....................................
.................. "l
L.,_HUMIDFIER I_,....
(24VAC)
il
A04221
Fig. 32 - Two Stage Thermostat with Single-Stage Furnace and Two-Speed Air Conditioner
NOTES FOR FIGURES 26-32
1. Heat pump MUST have a high pressure switch for dual fuel applications.
2. Refer to outdoor equipment Installation Instructions for additional information and setup procedure.
3. Outdoor Air Temperature Sensor nmst be attached in all dual fuel applications.
4. Dip switch No. 1 on Thermidistat should be set in OFF position for air conditioner installations. This is factory default.
5. Dip switch No. 1 on Thermidistat should be set in ON position for heat pump installations.
6. Dip switch No. 2 on Thermidistat should be set in OFF position for single-speed compressor operation. This is factory default.
7. Dip switch No. 2 on Thermidistat should be set in ON position for two-speed compressor operation.
8. Configuration Option No. 10 "Dual Fuel Selection" must be turned ON in all dual fuel applications.
9. NO connection should be made to the furnace HUM terminal when using a Thermidistat.
10. The RVS Sensing terminal "L" should not be connected. This is internally used to sense defrost operation.
11. DO NOT SELECT the "FURNACE INTERFACE" or "BALANCE POINT" option on the two-speed heat pump control board. This
is controlled internally by the Thermidistat/Dual Fuel Thermostat.
12. Dip switch D on Dual Fuel Thermostat should be set in OFF position for single-speed compressor operation. This is factory default.
13. Dip switch D on Dual Fuel Thermostat should be set in ON position for two-speed compressor operation.
27

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 58PHA Performance Boost 80 Series and is the answer not in the manual?

Carrier 58PHA Performance Boost 80 Series Specifications

General IconGeneral
BrandCarrier
Model58PHA Performance Boost 80 Series
CategoryFurnace
LanguageEnglish

Related product manuals