Carrier 58PHA Performance Boost 80 Series - Troubleshooting

Carrier 58PHA Performance Boost 80 Series
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
i
t_
o
o
START
Is LED status on?
light
YES
_--_ Is there 115V at L1 and L2? _ Is door switch closed?
I Isthere24VatSEC-1andSEC-2? I--E-P- I Is there 115V going to switch?
IRap'acefurnacec°ntr°k I IRap'aced°°rswitch
_ y
I Is LED status light blinking rapidly without apause?
,NO
I
Check for correct line voltage polarity. If units I
are twinned, check for proper low-voltage
I
(24V) transformer phasing.
_ Replace transformer.
Is LED status light blinking ON/OFF slowly
with a combination of short and long flashes?
I "
YES
Determine status code. The status code is a
2 digit number with the first digit determined
by the number of short flashes and the second
digit by the number of long flashes?
I Go to section belowforthe status code that _ Was there a previousstatus code
was flashed. _ other than #11?
To recall status code briefly remove and reconnect one RED wire from the draft
safeguard switch to display stored status code. On RED LED control do not
remove power or blower access panel before initiating status code recall. You
can also recall the previous status code by momentarily shorting the TESTfTWIN
terminal to Com24V terminal until the LED goes out. LED will flash the status
code of the previous fault or status code #11 (1 short and 1 long flash) if there
was no previous fault. After the control repeats the code 4 times, the control
will go through a brief component test sequence. The inducer will start and run
for the entire component test. The HSl, blower motor FAN speed (AMBER LED
boards only) HEAT speed, and COOL speed will run for 10 15 seconds each.
Gas valve and humidifier will not be turned on.
Does the control respond to W, Y1 (if present),
Y!Y2, and G (24V) thermostat signals?
V YES
Run system through a heating or cooling cycle
to check operation. Status codes are erased
after 72 hours. On RED LED boards stored
status codes can also be erased whenever
115V or 24V is interrupted.
I Replace furnace control.
_._ Is door switch closed?
_-_ Is circuit breaker closed? I_
l YES
I I check f°r c°ntinuily in wire fr°m circuit breakerItofurnace. I
I Close circuit breaker and go back to START. I_-
I heck room thermostat or
interconnecting cable.
' NO
Is24vpresentatW, l/ifpresent),orI
G thermostat terminals on the furnace control?
_ YES
I Disconnect all the thermostat wires from the I
furnace control.
I
l
I_._[ oes the problem repeat when usinga jumper wire?
,NO
The thermostat is not compatible with the
furnace control. Either install a ballast resistor,
connect the Com24V thermostat terminal to
the thermostat, or replace the thermostat.
NO