Table 3 — 30XA Minimum and Maximum Cooler Flow Rates
See Legend and Notes on page 118.
ITEM MINIMUM MAXIMUM
Cooler Leaving Water Temperature* 40 F (4.4 C) 60 F (15 C)
Cooler Entering Water Temperature† 45 F (7.2 C) 70 F (21.1 C)
30XA
UNIT SIZE
Nominal Flow Rate
Cooler
Number of
Passes
Minimum Flow Rate** Maximum Flow Rate
(gpm) (L/s) (gpm) (L/s) (gpm) (L/s)
080 180.4 11.4
Standard, Flooded 2 95 6 379 23.9
Plus One Pass, Flooded 3 43 2.7 192 12.1
Minus One Pass, Flooded 1 196 12.4 782 49.3
082 172.8 10.9 DX Cooler — 86 5.4 346 21
.8
090 201.9 12.7
Standard, Flooded 2 101 6.4 403 25.4
Plus One Pass, Flooded 3 43 2.7 200 12.6
Minus One Pass, Flooded 1 229 14.4 917 57.9
092 193.7 12.2 DX Cooler — 97 6.1 387 24.4
100 225.5 14.2
Standard, Flooded 2 101 6.4 403 25.4
Plus One Pass, Flooded 3 43 2.7 200 12.6
Minus One Pass, Flooded 1 229 14.4 917 57.9
102 214.3 13.5 DX Cooler — 107 6.7 429 27.0
110 244.9 15.5
Standard, Flooded 2 125 7.9 501 31.6
Plus One Pass, Flooded 3 61 3.8 244 15.4
Minus One Pass, Flo
oded 1 254 16 1014 64
112 235.2 14.8 DX Cooler — 118 7.4 470 29.6
120 264.8 16.7
Standard, Flooded 2 125 7.9 501 31.6
Plus One Pass, Flooded 3 73 4.6 293 18.5
Minus One Pass, Flooded 1 281 17.7 1124 70.9
122 254.7 16.0 DX Cooler — 127 8.0 509 32.1
140 317.8 20.1
Standard, Flooded 2 134 8.5 538 33.9
Plus One Pass, Flooded 3 73 4.6 293 18.5
Minus One Pass, Flooded 1 324 20.4 1296 81.8
142 303.5 19.1 DX Cooler — 152 9.6 607 38.2
160 365.1 23
Standard, Flooded 2 165 10.4 660 41.6
Plu
s One Pass, Flooded 3 98 6.2 391 24.7
Minus One Pass, Flooded 1 354 22.3 1418 89.5
162 347 21.9 DX Cooler — 174 10.9 694 43.7
180 409.6 25.8
Standard, Flooded 2 202 12.7 807 50.9
Plus One Pass, Flooded 3 73 4.6 391 24.7
Minus One Pass, Flooded 1 416 26.2 1662 104.9
182 401.7 25.3 DX Cooler — 201 12.6 803 50.6
200 463.9 29.3
Standard, Flooded 2 223 14.1 892 56.3
Plus One Pass, Flooded 3 98 6.2 391 24.7
Minus One Pass, Flooded 1 458 28.9 1833 115.6
202 447.1 28.2 DX Cooler
— 224 14.1 894 56.3
220 505.9 31.9
Standard, Flooded 2 235 14.8 941 59.4
Plus One Pass, Flooded 3 122 7.7 489 30.9
Minus One Pass, Flooded 1 501 31.6 2004 126.4
222 493 31.1 DX Cooler — 246 15.5 950 59.9
240 545.8 34.4
Standard, Flooded 2 266 16.8 1063 67.1
Plus One Pass, Flooded 3 147 9.3 587 37
Minus One Pass, Flooded 1 538 33.9 2151 135.7
242 530 33.5
DX Cooler — 265 16.7 950 59.9
260 600.3 37.9
Standard, Flooded 2 257 16.2 1027 64.8
Plus One Pass, Flooded 3 141 8.9 562 3
5.5
Minus One Pass, Flooded 1 584 36.8 2334 147.3
262 583 36.8 DX Cooler — 292 18.4 950 59.9
280 642.2 40.5
Standard, Flooded 2 293 18.5 1173 74
Plus One Pass, Flooded 3 141 8.9 562 35.5
Minus One Pass, Flooded 1 620 39.1 2481 156.5
282 627 39.5 DX Cooler — 313 19.8 950 59.9
300 687.5 43.4
Standard, Flooded 2 327 20.6 1308 82.5
Plus One Pass, Flooded 3 174 11 697 44
Minus One Pass, Flooded 1 687 43.3 2750 173.5
302 665 42.0 DX Cooler — 333 21.0 1331 83.9
325 733.4 46.3
Stand
ard, Flooded 2 361 22.8 1442 91
Plus One Pass, Flooded 3 211 13.3 843 53.2
Minus One Pass, Flooded 1 724 45.7 2897 182.8
327 720 45.4 DX Cooler — 360 22.7 1440 90.8
350 775.4 48.9
Standard, Flooded 2 379 23.9 1516 95.6
Plus One Pass, Flooded 3 244 15.4 978 61.7
Minus One Pass, Flooded 1 767 48.4 3068 193.6
352 757 47.8 DX Cooler — 379 23.9 1514 95.5
400 917.6 57.9
Standard, Flooded 1 501 31.6 2004 126.4
Plus One Pass, Flooded — — — — —
Minus One Pass, Flooded — — — — —