Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53300166-01 Printed in U.S.A. Form 30XV-1T Pg 1 4-17 Replaces: New
Controls, Start-Up, Operation, Service
and Troubleshooting
CONTENTS
Page
SAFETY CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . .2,3
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,4
Conventions Used in This Manual. . . . . . . . . . . . . . . . 4
Abbreviations Used in This Manual . . . . . . . . . . . . . . 4
CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Touch Pilot™ Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Touch Pilot Display User Interface . . . . . . . . . . . . . . . 4
WELCOME SCREEN
HOME SCREEN
STATUS MESSAGE BOX
TOUCH PILOT LOGIN AND DISPLAY SETUP
MAIN MENU SCREEN
GENERAL CONFIGURATION TABLE
TRENDINGS SCREEN
MENU ARCHITECTURE
SETTING TIME AND DATE
WEB AND NETWORK INTERFACE
Input/Output (SIOB) Boards . . . . . . . . . . . . . . . . . . . 11
Auxiliary (AUX) Boards. . . . . . . . . . . . . . . . . . . . . . . . . . 11
Enable-Off-Remote Contact Switch (SW1). . . . . . . 15
Emergency On/Off Switch (SW2) . . . . . . . . . . . . . . . . 15
Energy Management Module (EMM) . . . . . . . . . . . . . 15
Local Equipment Network. . . . . . . . . . . . . . . . . . . . . . . 16
Board Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Control Module Communication . . . . . . . . . . . . . . . . 16
•RED LED
GREEN LED
Carrier Comfort Network
®
(CCN) Interface . . . . . . 16
Remote Alarm and Alert Relays . . . . . . . . . . . . . . . . . 17
CONFIGURATION (SOFTWARE) . . . . . . . . . . . . 17-43
Touch Pilot Operation Configuration Tables . . . . 17
Touch Pilot Menu Tables. . . . . . . . . . . . . . . . . . . . . . . . 17
Machine Control Methods . . . . . . . . . . . . . . . . . . . . . . . 20
OPERATING TYPE SELECTION
Machine On/Off Function . . . . . . . . . . . . . . . . . . . . . . . 21
MACHINE START DELAY
FAST LOADING
Chilled Water Setpoint Configuration . . . . . . . . . . . 22
FLUID SETPOINT CONTROL LOCATION
COOLING SETPOINT SELECTION
DEFINING SET POINTS
CURRENT OPERATING SETPOINT
SETPOINT OCCUPANCY
DEFINING OCCUPANCY SCHEDULE
CHILLED WATER FLUID TYPE SELECTION
Evaporator Pump Control . . . . . . . . . . . . . . . . . . . . . . . 25
PUMP SELECTION
PERIODIC PUMP QUICK START
MASTER/SLAVE CHILLER PUMP OPERATION
CHILLED WATER FLOW SWITCH STATUS
MANUAL OPERATION
Page
Circuit/Compressor Staging and Loading . . . . . . . 26
CIRCUIT/COMPRESSOR STAGING
CIRCUIT/COMPRESSOR LOADING/UNLOADING
Dual Chiller Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DUAL CHILLER CONTROL FOR PARALLEL
APPLICATIONS
DUAL CHILLER PUMP CONTROL FOR PARALLEL
CHILLER APPLICATIONS
DUAL CHILLER CONTROL FOR SERIES
CHILLER APPLICATIONS
DUAL CHILLER PUMP CONTROL FOR SERIES
CHILLER APPLICATIONS
Ramp Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Temperature Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
OUTSIDE AIR TEMPERATURE RESET
DELTA T RESET (RETURN WATER RESET)
4-20 mA TEMPERATURE RESET
SPACE TEMPERATURE RESET
Demand Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
SWITCH CONTROLLED DEMAND LIMIT
EXTERNALLY POWERED (4 to 20 mA) DEMAND
LIMIT
CCN LOADSHED CONTROLLED DEMAND LIMIT
Ice Storage Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Broadcast Configuration . . . . . . . . . . . . . . . . . . . . . . . . 40
ACTIVATE
OAT BROADCAST
BROADCAST ACKNOWLEDGER
Alarm Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
ALARM ROUTING CONTROL
ALARM EQUIPMENT PRIORITY
COMMUNICATION FAILURE RETRY TIME
RE-ALARM TIME
ALARM SYSTEM NAME
Daylight Saving Time Configuration. . . . . . . . . . . . . 41
Capacity Control Overrides . . . . . . . . . . . . . . . . . . . . . 41
Head Pressure Control (Variable Speed Fans) . . 42
Head Pressure Control (Fixed Speed Fans) . . . . . 42
PRE-START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
System Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43-46
Actual Start-Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Operating Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
TEMPERATURES
VOLTAGE
MINIMUM FLUID LOOP VOLUME
FLOW RATE REQUIREMENTS
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47-52
Sequence of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . 47
ACTUATED BALL VALVE (ABV)
AquaForce
®
30XV140-325
Variable Speed Air-Cooled Liquid Chillers
with Greenspeed
®
Intelligence
and Touch Pilot
Controls

Table of Contents