Fig. 5 — 30MP Model Number Nomenclature
30MP
A
030
6
-
30MP – AquaSnap
®
Liquid Chiller with ComfortLink Controls
Condenser Option
A – Chiller without Condenser (Air-Cooled)
Design Revision Level
W – Chiller with Condenser (Water-Cooled)
- – Initial Release
Voltage Options
1 – 575-3-60
5 – 208/230-3-60
6 – 460-3-60
Unit Size Nominal Tons (kW)
016– 15 (53)** 050 – 50 (176)
055 – 55 (194)
060 – 60 (211)
065 – 65 (229)
020 – 20 (70)
03030 (106)
03230 (106)**
040 – 40 (141)
045 – 45 (158)
2380-3-60
0
0
Water Manifold/Brine Options
0
Capacity Control/High Interrupt Options
0Standard
0
0
Controls/Interface Options
5Scrolling Marquee Display, EMM
6Scrolling Marquee Display with BACnet
Communication Option and EMM
5
Packaging Options
5 – Bag, No Compressor Insulation (Std)
7 – Bag, Compressor Insulation
B – Export Crating, No Compressor Insulation
D – Export Crating, Compressor Insulation
1 – Hot Gas Bypass
2 – Digital Compressor*
3 – High Interrupt
4 – High Interrupt and
Hot Gas Bypass
5 – High Interrupt and
Digital Compressor
Sound/Mounting Options
0 – None
1Sound Enclosure Panel
s
3 – Height Adjustment Kit
4 – Height Adjustment Kit, Sound Enclosure Panels
9 – Mobility Kit (Wheels)
B – Mobility Kit (Wheels), Sound Enclosure Panels
D – Height Adjustment Kit, Mobility Kit (Wheels)
F – Height Adjustment Kit, Mobility Kit (Wheels), Sound Enclosure Panels
L – Compressor Sound Blankets
M
– Compressor Sound Blankets, Mobility Kit (Wheels)
N – Compressor Sound Blankets, Height Adjustment Kit
P – Compressor Sound Blankets, Mobility Kit (Wheels), Height Adjustment Kit
2 – Water Manifold Sound Enclosure Panels
5 – Height Adjustment Kit, Water Manifold Sound Enclosure Panels
G – Height Adjustment Kit, Mobility Kit (Wheels), Water Manifold Sound
Enclosure Panels
0Scrolling Marq
uee Display (Std)
1 Scrolling Marquee Display with BACnet
Communication Option
Disconnect Options
0Standard (Terminal Block)
1 – Non-Fused Disconnect Switch
9380/415-3-50
6 – High Condensing†
7 – High Condensing† and
Hot Gas Bypass
8 – High Interrupt and
High Condensing†
9 – High Interrupt,
High Condensing†,
and Hot Gas Bypass
071 – 71 (250)
2 – Fused Disconnect Switch (selected model
s)††
0 – Comfort Cooling Duty (32°-60°F) (0.0°-16.5°C) (Std)
1 – Water Manifold Piping (Includes Combination Valve)
2 – Water Manifold Piping and Evaporator Isolation
(Includes Combination Valve)
3 – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve)
4 – Water Manifold Piping, Evaporator Isolation and
Head Pressure Control (Includes Combination Valve)
5 – W
ater Manifold Piping and Evaporator Isolation
(Includes Combination Valve) Medium Temperature Brine
6 – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve) Medium Temperature Brine
7 – Medium Temperature Brine (15°-32°F) (–9.4°-0.0°C)
8 – Water Manifold Piping (Includes Combination Valve),
Medium Temperature Brine
9 – Water Manifold Piping, Evaporator Isolation
and
Head Pressure Control (Includes Combination Valve),
Medium Temperature Brine
B – Nitrogen Charge
C – Water Manifold Piping (Includes Combination Valve),
Nitrogen Charge
D – Water Manifold Piping and Evaporator Isolation
(Includes Combination Valve), Nitrogen Charge
F – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve), Nitrogen Charge
H – Medium Temperature Brine, Nitrogen Ch
arge
J – Water Manifold Piping and Evaporator Isolation
(Includes Combination Valve), Medium Temperature Brine,
Nitrogen Charge
K – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve), Medium Temperature Brine,
Nitrogen Charge
L – Water Manifold Piping, Evaporator Isolation and
Head Pressure Control (Includes Combination Valve),
Medium Temperatu
re Brine, Nitrogen Charge
LEGEND
* Digital compressor available on models 016-045 only.
High condensing options available on models 050-071 only.
High condensing option is standard on models 020, 030, 040,
045, High condensing option is not available on models 016
and 032.
** 016 and 032 are only available in 30MPW configurations.
30MPA configurations are not available for 016 and 032 units.
†† Fused Disconnect is required for 016 and 032 units equipped
with the High Interrupt Option. Fused Disconnect is NOT avail-
able for any other units.