30MP
A
030
6
-
30MP – AquaSnap
®
Liquid Chiller with ComfortLink Controls
Condenser Option
A – Chiller without Condenser (Air-Cooled)
Design Revision Level
W – Chiller with Condenser (Water-Cooled)
- – Initial Release
Voltage Options
1 – 575-3-60
5 – 208/230-3-60
6 – 460-3-60
Unit Size – Nominal Tons (kW)
016– 15 (53)** 050 – 50 (176)
055 – 55 (194)
060 – 60 (211)
065 – 65 (229)
020 – 20 (70)
030 – 30 (106)
032 – 30 (106)**
040 – 40 (141)
045 – 45 (158)
2 – 380-3-60
0
0
Water Manifold/Brine Options
0
Capacity Control/High Interrupt Options
0 – Standard
0
0
Controls/Interface Options
5 – Scrolling Marquee Display, EMM
6 – Scrolling Marquee Display with BACnet
Communication Option and EMM
5
Packaging Options
5 – Bag, No Compressor Insulation (Std)
7 – Bag, Compressor Insulation
B – Export Crating, No Compressor Insulation
D – Export Crating, Compressor Insulation
1 – Hot Gas Bypass
2 – Digital Compressor*
3 – High Interrupt
4 – High Interrupt and
Hot Gas Bypass
5 – High Interrupt and
Digital Compressor
Sound/Mounting Options
0 – None
1 – Sound Enclosure Panel
s
3 – Height Adjustment Kit
4 – Height Adjustment Kit, Sound Enclosure Panels
9 – Mobility Kit (Wheels)
B – Mobility Kit (Wheels), Sound Enclosure Panels
D – Height Adjustment Kit, Mobility Kit (Wheels)
F – Height Adjustment Kit, Mobility Kit (Wheels), Sound Enclosure Panels
L – Compressor Sound Blankets
M
– Compressor Sound Blankets, Mobility Kit (Wheels)
N – Compressor Sound Blankets, Height Adjustment Kit
P – Compressor Sound Blankets, Mobility Kit (Wheels), Height Adjustment Kit
2 – Water Manifold Sound Enclosure Panels
5 – Height Adjustment Kit, Water Manifold Sound Enclosure Panels
G – Height Adjustment Kit, Mobility Kit (Wheels), Water Manifold Sound
Enclosure Panels
0 – Scrolling Marq
uee Display (Std)
1 – Scrolling Marquee Display with BACnet
Communication Option
Disconnect Options
0 – Standard (Terminal Block)
1 – Non-Fused Disconnect Switch
9 – 380/415-3-50
6 – High Condensing†
7 – High Condensing† and
Hot Gas Bypass
8 – High Interrupt and
High Condensing†
9 – High Interrupt,
High Condensing†,
and Hot Gas Bypass
071 – 71 (250)
2 – Fused Disconnect Switch (selected model
s)††
0 – Comfort Cooling Duty (32°-60°F) (0.0°-16.5°C) (Std)
1 – Water Manifold Piping (Includes Combination Valve)
2 – Water Manifold Piping and Evaporator Isolation
(Includes Combination Valve)
3 – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve)
4 – Water Manifold Piping, Evaporator Isolation and
Head Pressure Control (Includes Combination Valve)
5 – W
ater Manifold Piping and Evaporator Isolation
(Includes Combination Valve) Medium Temperature Brine
6 – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve) Medium Temperature Brine
7 – Medium Temperature Brine (15°-32°F) (–9.4°-0.0°C)
8 – Water Manifold Piping (Includes Combination Valve),
Medium Temperature Brine
9 – Water Manifold Piping, Evaporator Isolation
and
Head Pressure Control (Includes Combination Valve),
Medium Temperature Brine
B – Nitrogen Charge
C – Water Manifold Piping (Includes Combination Valve),
Nitrogen Charge
D – Water Manifold Piping and Evaporator Isolation
(Includes Combination Valve), Nitrogen Charge
F – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve), Nitrogen Charge
H – Medium Temperature Brine, Nitrogen Ch
arge
J – Water Manifold Piping and Evaporator Isolation
(Includes Combination Valve), Medium Temperature Brine,
Nitrogen Charge
K – Water Manifold Piping and Head Pressure Control
(Includes Combination Valve), Medium Temperature Brine,
Nitrogen Charge
L – Water Manifold Piping, Evaporator Isolation and
Head Pressure Control (Includes Combination Valve),
Medium Temperatu
re Brine, Nitrogen Charge