INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS
Translation of the original document
* The availability of sizes and options depends on the country. Please contact your local commercial dealer for more information.
Air-Cooled Liquid Chillers
Reversible heat pumps
30RB/30RQ 040R-160R
Rated cooling capacity 40-160 kW
R-32

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier Aquasnap 30RB 045R and is the answer not in the manual?

Carrier Aquasnap 30RB 045R Specifications

General IconGeneral
Model30RB 045R
CategoryChiller
Cooling Capacity45 kW
Compressor TypeScroll
RefrigerantR-410A
Power Supply400V/3ph/50Hz
Dimensions (L x W x H)1800 x 800 x 1600 mm
Weight400 kg
Operating Range-10°C to 45°C

Summary

Handling and Positioning

Handling

Guidelines for safe lifting and moving of the unit using specialized personnel and equipment.

Positioning

Requirements for outdoor installation, level surface, and adequate clearances for operation and maintenance.

Physical and Electrical Data for the Units

Electrical Data Notes: 30RB/30RQ 040R-160R

Detailed electrical specifications including voltage, current, power input, and start-up current.

Electrical Connection

Power Supply

Requirements for the power supply, voltage range, and warnings about incorrect supply.

Recommended Cable Sections

Guidelines for selecting appropriate cable sizes based on unit current and installation conditions.

Application Data

Operating Range

Defines the minimum and maximum ambient and water temperatures for unit operation.

Water Connections

Operating Precautions and Recommendations

Key checks and recommendations before connecting hydraulic circuits to heat exchangers.

Variable-Speed Pump - Pressure Differential Control

How the unit controls flow rate using pressure differential with variable speed pumps.

Nominal System Water Flow Rate Control

System Start-Up

Checks Before System Start-Up

Comprehensive checklist of installation and safety checks required before initial unit operation.

Essential Points to Check

Specific checks for compressors, hydraulics, and refrigerant charge during start-up.

Main Components of the Unit and Operating Characteristics

Compressors

Details on the hermetically sealed scroll compressors used in the units.

SmartVu™ Control

Overview of the unit's control interface, features, and user experience.

Standard Maintenance

Unit Start-Up Checklist for Installers Prior to Contacting the Manufacturer

Preliminary Equipment Check

Checklist for verifying the unit's physical condition and installation compliance.

Unit Start-Up

Steps for initiating the unit's start-up sequence and final checks.