COMBINATION RATINGS CONTINUED
Unit Size ---
Voltage &
Series
Indoor
Model
To t a l C ap .
BTUH
Factory
Supplied
Enhancement
SEER
EER
Furnace
Model
Standard
Rating
TDR{
48---30
CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 58CV(A,X)090---16
CNPH*4821A** 45,500 TDR&TXV 13.50 11.20 58CV(A,X)110---20
CNPH*6024A** 47,000 TXV 13.20 11.00
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58MVB080---20
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58MVB100---20
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58CV(A,X)090---16
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58CV(A,X)110---20
CNPF*4818A** 45,000 TXV 13.00 11.00
CSPH*4812A** 46,000 TXV 13.00 11.00
CSPH*4812A** 45,000 TDR&TXV 13.20 11.00 58MVB080---20
CSPH*4812A** 45,500 TDR&TXV 13.50 11.20 58CV(A,X)090---16
CSPH*6012A** 47,000 TXV 13.20 11.00
CSPH*6012A** 46,000 TDR&TXV 13.50 11.20 58MVB080---20
CSPH*6012A** 46,000 TDR&TXV 13.50 11.20 58CV(A,X)090---16
FX4CN(B,F)048 47,000 TDR&TXV 13.50 11.20
FX4CN(B,F)060 47,500 TDR&TXV 14.00 11.50
FV4BNF005 46,500 TDR&TXV 14.00 11.50
FV4BNB006 47,000 TDR&TXV 14.00 11.70
FY4ANF048 46,000 TDR&TXV 13.00 11.00
FY4ANB060 46,500 TDR&TXV 13.20 11.00
60---30
CAP**6021A** 56,500 TXV 13.00 11.00
CAP**6021A** 56,000 TDR&TXV 13.20 11.00 58CV(A,X)110---20
*CAP**6024A** 57,500 TXV 13.00 11.00
CAP**6024A** 56,500 TDR&TXV 13.20 11.00 58CV(A,X)135---22
CAP**6024A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)155---22
CNPV*6024A** 57,000 TXV 13.00 11.00
CNPV*6024A** 56,000 TDR&TXV 13.50 11.00 58CV(A ,X)135---22
CNPV*6024A** 56,500 TDR&TXV 13.50 11.20 58CV(A ,X)155---22
CNPH*6024A** 57,000 TXV 13.00 11.00
CNPH*6024A** 56,000 TDR&TXV 13.50 11.20 58CV(A,X)135---22
CNPH*6024A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)155---22
CSPH*6012A** 57,500 TXV 13.00 11.00
CSPH*6012A** 56,500 TDR&TXV 13.20 11.00 58CV(A,X)110---20
CSPH*6012A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)135---22
CSPH*6012A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)155---22
FX4CN(B,F)060 58,000 TDR&TXV 13.20 11.00
FV4BNB006 57,000 TDR&TXV 13.50 11.20
FY4ANB060 56,500 TDR&TXV 13.00 11.00
* Tested combination
{ In most cases, only 1 method should be u sed to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time---Delay Relay KAAT D0101TDR or a furnace equipped with TDR. Most Carrier furnaces are e quipped with TDR.
EER Energy Efficiency Ratio
SEER Seasonal Energy Efficiency Ratio
TDR T i m e --- D e la y R el a y
TXV Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air con ditione rs. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
24ABA3