PHYSICAL DATA
UNIT SIZE SERIES 18 24 30 36 42 48 60
Operating Weight (lb) 125 125 134 152 189 210 236
Shipping Weight (lb) 146 146 155 175 218 235 270
Compressor Type Scroll
REFRIGERANT Puron® (R---410A)
Control TXV (Puron® Hard Shutoff)
Charge (lb) 4.25 4.35 4.75 5.25 6.2 8.35 8.75
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1880 2200 2200 2950 3170 3365 4050
Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/5
Motor RPM 1100 1100 1100 1100 1100 1100 825
COND COIL
Face Area (Sq ft) 9.85 9.85 11.49 14.77 17.25 21.56 25.15
Fins per In. 20 20 25 25 25 25 25
Rows 1 1 1 1 1 1 1
Circuits 3 3 3 3 4 5 5
VALVECONNECT.(In.ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
REFRIGERANT TUBES* (In. OD)
Vapor (0---80 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8
Liquid (0--- 80 Ft Tube Length) 3/8”
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
PURON 1--STAGE AIR CONDITIONER APPLICATIONS
LONG LINE APPLICATION: An application is considered
”Long line” when the total equivalent tubing length exceeds 80 ft
or when there is more than 20 Ft vertical separation between
indoor and outdoor units. These applications require additional
accessories and system modifications for reliable system
operation. The maximum allowable total equivalent length is
250Ft. The maximum vertical separation is 200 Ft when outdoor
unit is above indoor unit, and up to 80 Ft when the outdoor unit
is below the indoor unit. Refer to Accessory Usage Guideline
below for required accessories. See Long--Line Application
Guideline for required piping and system modifications. Also,
refer to the table below for the acceptable vapor tube diameters
based on the total length to minimize the cooling capacity loss.
Unit Nominal Size
(Btuh)
Acceptable
Vapor Line
Diameters
(In. OD)
Cooling Capacity Loss (%)
Total Equivalent Line Length (ft)
Standard Application Long Line Application Requires Accessories
25 50 80 80+ 100 125 150 175 200 225 250
18000
1StagePuronAC
1/2 1 2 4 4 5 6 7 8 10 11 12
5/8 0 1 1 1 2 2 2 3 3 3 4
24000
1StagePuronAC
5/8 1 1 2 2 3 3 4 4 5 6 6
3/4 0 1 1 1 1 1 1 2 2 2 2
7/8 0 0 0 0 1 1 1 1 1 1 1
30000
1StagePuronAC
5/8 1 2 3 3 4 5 6 7 8 9 9
3/4 0 1 1 1 1 2 2 3 3 3 4
7/8 0 0 1 1 1 1 1 1 1 2 2
36000
1StagePuronAC
5/8 1 3 4 4 5 7 8 9 11 12 13
3/4 1 1 2 2 2 3 3 3 4 4 5
7/8 0 1 1 1 1 1 2 2 2 2 3
42000
1StagePuronAC
3/4 1 1 2 2 3 3 4 5 5 6 7
7/8 0 1 1 1 1 2 2 2 3 3 3
11/8 0 0 0 0 0 1 1 1 1 1 1
48000
1StagePuronAC
3/4 1 2 3 3 3 4 5 6 7 8 8
7/8 0 1 1 1 2 2 3 3 3 4 4
11/8 0 0 0 0 1 1 1 1 1 1 1
60000
1StagePuronAC
3/4 1 3 4 4 5 6 8 9 10 11 13
7/8 1 1 2 2 3 3 4 4 5 6 6
11/8 0 0 1 1 1 1 1 1 1 2 2
Standard Length = 80 Ft or less total equivalvent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is b elow indoor unit See
Long Line Application Guidelines
24ABA3