915SB: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
3
A210210
Fig. 1 – Dimensional Drawing
SAFETY CONSIDERATIONS
FURNACE SIZE
A B C D
SHIP WT.
LB (KG)
CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE
30026E14 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 118.5 (53.7)
30040E14 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 120 (54.4)
36040E17 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 126.5 (57.4)
36060E14 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 129 (58.5)
42060E17 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 138.5 (62.8)
48080E17 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 146.5 (66.4)
60080E21 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 154.5 (70.1)
60100E21 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 164.5 (74.6)
66100E21 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 164.5 (74.6)
66120E24 24-1/2 (622) 22-7/8 (581) 23 (584) 12-1/4 (311) 179.5 (81.4)
66140E24 24-1/2 (622) 22-7/8 (581) 23 (584) 12-1/4 (311) 189 (85.7)
U.S. ECCN: Not Subject to Regulation (N.S.R.)
SD5660-4 REV. -
NOTE: ALL DIMENSIONS IN INCH (MM)
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause carbon monoxide poisoning, explosion, fire, electrical
shock, or other conditions which may cause personal injury or property
damage. Consult a qualified service agency, local gas supplier, or your
distributor or branch for information or assistance. The qualified
service agency must use only factory-authorized and listed kits or
accessories when modifying this product.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage.
Furnaces shall NOT be twinned (i.e. tandem or staged operation) unless
approved in factory technical specifications literature for the furnace.
A factory authorized, field-supplied Twinning Kit MUST be used.
Consult furnace pre-sale literature for specific models approved for
twinning and the correct twinning kit. Twinned furnaces must be
installed on both a common supply AND a common return duct system
as shown in the Twinning Kit Installation Instructions. Only two
furnaces can be twinned on a common supply and return duct system
using a factory authorized twinning kit.