12
62--10601
START- STOP OPERATION
FAULT STAND-BY
START/STOP
FUNCTION
CHANGE
UNIT
DA TA
PRETRIP
CHECK
AUTO S/S
CONTINUOUS
MANUAL
DEFROST
ENTER
SETPOINT BOX TEMPERATURE
FAULT
STANDBY
POWER ON
1
0
START/RUN
OFF
STANDBY
ENGINE
-
--
-2
22
20
00
0.
..
.0
00
03
33
34
44
4.
..
.5
55
5°
°°
°F
FF
F
1. Press the AUTO S/S-CONTINUOUS
toggle key until START-STOP is
displayed. Unit is now in Automatic
Start/Stop mode.
START/STOP
Automatic start/stop is provided to permit starting/restarting of the
diesel-driven compressor as required. This gives the
microprocessor automatic control of starting and stopping the
diesel engine. The main function of automatic start-stop is to turn
off the refrigeration system near the setpoint to provide a fuel
efficient temperature control system and then restart the engine
when needed. Start-Stop operation is normally used for frozen
loads. Refer to R
ECOMMENDED TRANSPOR T TEMPERATURES (SeePage
32).