Carrier Transicold Vector User Manual

Carrier Transicold Vector
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
62-60556-00
Auto Start/Stop
Continuous Run
Temperature Setpoint
Pretrip Check
Alarm Display/Reset
Trip Start
Function Change
Unit Data
Manual Defrost
Manual Operation
Standby Operation
Stopping
EASY TO RUN
CHECK OUT
THESE FUNCTIONS
CARRIER TRANSICOLD EUROPE S.A.S.
10-12, bd de l’Oise
F-95031 CERGY PONTOISE CEDEX
Phone : + 33 (0) 1 34 43 48 00 - Fax : + 33 (0) 1 34 43 48 48
MESSAGES SPELLED
OUT IN 8 LANGUAGES
MESSAGES SPELLED
OUT IN 8 LANGUAGES
500 CARRIER SERVICE STATIONS in EUROPE,
FORMER SOVIET UNION, MIDDLE EAST and AFRICA
Our company is constantly seeking to improve the quality of its products and, therefore,
reserves the right to modify its products without prior notice
Carrier Transicold Europe S.A.S. - S.A.S. au capital de 16 090 700 euros
R.C.S. Pontoise B 410 041 776 - Code APE 292 F - VAT : FR52410041776
The information contained in this document is not contractually binding,
and may not be reproduced without prior approval - 62-60556-00
Question and Answer IconNeed help?

Do you have a question about the Carrier Transicold Vector and is the answer not in the manual?

Carrier Transicold Vector Specifications

General IconGeneral
ModelVector
TypeTransport Refrigeration Unit
Power SourceDiesel, Electric standby
Cooling CapacityVaries by model
WeightVaries by model
DimensionsVaries by model
RefrigerantR-452A
Operating ModesContinuous, Start-Stop
Temperature Range-29°C to +27°C (-20°F to +80°F) (typical range, may vary by model)

Summary

Safety and Unit Stopping Procedures

General Safety Precautions

Highlights critical safety warnings for operating and servicing the Carrier refrigeration unit, including high voltage risks.

Stopping the Unit

Provides the essential step to safely stop the refrigeration unit by placing the RUN/STOP switch in the STOP position.

Standby Operation with LogiCOLD

LogiCOLD Control System Overview

Details the LogiCOLD microprocessor control system for Vector units, emphasizing reliability and user-friendly operation across multiple languages.

Starting and Operating Modes

Auto Start / Stop Operation

Guides through the process of enabling automatic start and stop functions, including language selection and mode confirmation.

Manual Operation Guide

Explains the steps for manual unit operation, including preheating, starting the engine, and engaging the crank function.

Defrost and Continuous Run Modes

Manual Defrost Procedure

Details how to initiate a manual defrost cycle, including display messages and conditions under which defrosting is prevented.

Continuous Run Mode

Instructs on activating and verifying the continuous run mode for the refrigeration unit, ensuring constant operation.

Setting and Viewing Unit Data

Temperature Setpoint Adjustment

Guides users on how to change and save the temperature setpoint using the unit's interface, with confirmation messages.

Accessing Unit Data

Explains how to navigate and view various unit data parameters using the SELECT key and arrow keys on the controller.

Function Management and Pre-trip Checks

Function Change Procedure

Details the process for changing various unit functions, including scrolling through options and saving new settings via the message center.

Pretrip Check Execution

Outlines the steps to perform a pretrip check, including initiating the test sequence and verifying the test number displayed.

Alarm and Trip Management

Alarm Display and Reset

Explains how to display active alarms, scroll through the alarm list, and clear alarms from the system.

Trip Start Recording

Guides on how to mark the start of a trip in the data recorder, including confirmation messages upon successful entry.