User and Installer Manual
A200557
INSTALLER: READ THESE INSTRUCTIONS BEFORE INSTALLING UNIT.
SAVE THEM FOR THE USER.
RESIDENTIAL USE ONLY
REGISTER YOUR PRODUCT ONLINE AT: www.cac-bdp-all.com For additional information, https://www.hvacpartners.com/
A200637
65% SRE ERV Models are not ENERGY STAR certified
Consumer Information
A. To ensure quiet operation of the ENERGY STAR certified H/ERV, each product model must be installed using sound attenuation techniques
appropriate for the installation.
B. The way your heat/energy-recovery ventilator is installed can make a significant difference to the electrical energy you use. To minimize the
electricity use of the heat/energy-recovery ventilator, a stand-alone fully ducted installation is recommended. If you choose a simplified installation
that operates your furnace air handler for room-to-room ventilation, an electrically efficient furnace that has an electronically commutated (EC)
variable speed blower motor will minimize your electrical energy consumption and operating cost.
ERV & HRV
Fresh Air Systems
ERVXXSHA1130, ERVXXSVA1130, HRVXXSHA1130, HRVXXSVA1130
ERVXXSHA1150, ERVXXSVA1150, ERVXXSHB1145, ERVXXSVB1145
HRVXXSHA1160, HRVXXSVA1160, HRVXXSHB1160, HRVXXSVB1160

Questions and Answers

  • K
    Kelly LopezJul 25, 2025
    What to do if my Carrier HRVXXSHB1160 shows error E24?
    • R
      robertomasonJul 25, 2025
      If your Carrier Air Cleaner displays error code E24, it could be due to a severe fluctuation in your in-house power supply, which is a protection mechanism to stop the motor. First, try unplugging and plugging the unit back in. If the problem persists, the electronic assembly may need to be replaced.
  • B
    bboydAug 4, 2025
    What to do if Carrier Air Cleaner displays E23 error?
    • K
      Kimberly WrightAug 4, 2025
      To resolve error code E23 on your Carrier Air Cleaner: * Start by unplugging and plugging the unit back in. * If that doesn't work, remove the core and clear the ventilation wheel of any dirt or obstacles. * If the problem continues, disconnect J2 (white) and connect a spare blower system. If it works, replace the supply blower. * If these steps do not fix the error, the electronic assembly may need replacing.
  • L
    Lucas GayAug 9, 2025
    How to troubleshoot E09 error on Carrier HRVXXSHB1160?
    • K
      Kayla JohnsonAug 9, 2025
      To troubleshoot error E09 on your Carrier Air Cleaner: * Begin by unplugging the unit and inspecting the damper system for any obstructions or dirt. You might need to remove the filters and core to fully access the damper system. Then, plug the unit back in. * If the error persists, open the electrical compartment and check if connector J6 (blue) is properly inserted and look for any loose wires. * If the damper isn't moving at all, unplug J5 (white) from the electronic assembly and connect the blue damper system connector into J5. If the damper moves but the system still shows an error, the electronic assembly likely needs to be replaced. Otherwise, replace the damper system.
  • M
    Michelle AdamsAug 15, 2025
    How to troubleshoot E05 error on Carrier HRVXXSHB1160?
    • D
      Donna BanksAug 15, 2025
      To troubleshoot error E05 on your Carrier Air Cleaner: * First, unplug the unit and inspect the damper system, removing any obstructions or dirt. You might need to remove filters and the core to access the damper system. Then, plug the unit back in. * If the problem continues, open the electrical compartment and check if connector J7 (red) is properly inserted and look for any loose wires. * If the damper isn't moving, unplug J5 (white) from the electronic assembly and connect the white damper system connector into J5. If the damper moves but the error persists, the electronic assembly likely needs replacement. Otherwise, replace the damper system.
  • J
    James ClayAug 20, 2025
    How to troubleshoot E01 error on Carrier HRVXXSHB1160 Air Cleaner?
    • T
      Tracy MccarthyAug 20, 2025
      To troubleshoot error E01 on your Carrier Air Cleaner: * Unplug the unit, inspect the damper system, and remove any obstacles or dirt. You might need to remove filters and the core to access the damper system. Then, plug the unit back in. * If the error continues, open the electrical compartment and check if connector J5 (white) is properly inserted and look for any loose wires. * If the damper isn't moving at all, unplug J7 (red) from the electronic assembly and connect the white damper system connector into J7. If the damper moves but the system still shows an error, the electronic assembly likely needs to be replaced. Otherwise, replace the damper system.
  • S
    smithannaOct 29, 2025
    How to fix error E22 on a Carrier Air Cleaner?
    • A
      Anthony VaughnOct 29, 2025
      To address error code E22 on your Carrier Air Cleaner: * Begin by visually inspecting the supply damper system. Ensure you clean the filters, distribution registers, and the outside supply hood. Also, check the ducting to make sure it's not squeezed or bent. * If the issue continues, remove the ducting from the supply path and check if the unit can reach the selected flow by choosing MAX on the LCD screen. If it reaches the flow, then examine the ducting path. * If the problem still isn't resolved, select the MIN and MAX flow setting values on the LCD screen, then reset the unit. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. * If none of these steps work, the supply blower or the electronic assembly may need to be replaced. Repeat step 3 after...

Summary

LIMITATION

RESIDENTIAL INSTALLATION ONLY

Specifies that the unit is intended for residential (domestic) installation only.

INSTALLATION

LOCATING AND MOUNTING THE UNIT

Guidance on selecting an appropriate location and securely mounting the unit.

INSTALLING THE DUCTWORK AND THE REGISTERS

CONNECTING THE DUCTS TO THE UNIT

INSULATED FLEXIBLE DUCTS

Procedure for connecting insulated flexible ducts to the unit ports.

CONNECTIONS

ELECTRICAL CONNECTION TO OPTIONAL MAIN WALL CONTROL

Instructions for the electrical connection of optional main wall controls.

OPTIONAL WALL CONTROL CONNECTIONS

Connecting speed selectors, dehumidistats, or premium optional main wall controls.

CONNECTION TO THE FURNACE;AHU

WIRING DIAGRAM

UNIT AUTO-BALANCING

AUTO-BALANCING PROCEDURE

Step-by-step guide for performing the unit's auto-balancing procedure.

INSTALLERS TROUBLESHOOTING

INSTALLERS TROUBLESHOOTING (CONTD)

MAINTENANCE

ANNUAL (AT FALL)

USERS TROUBLESHOOTING