SETUP MENU
This menu has several layers, allowing modification of equipment
settings. No settings will need to be made at equipment (i.e.dip
switches on a furnace). All configuration settings are made
effective fi'om this menu. Fig. 23 shows all the inlbrmation that
can be found in the SETUP menu.
SETUP
THERMOSTAT
FURNACE
HEAT PUMP
ACCESSORIES
SYSTEM MAINTENANCE
< BACK SELECT>
Fig. 23 -- SETUP MENU
A03203
SETIP = THERMOSTAT:
AUTO MODE SETUP:
Enable_isable Auto Changeover mode (default Enable).
Auto Changeover Time may be adjusted 5 to 120 minutes,
(default 30 minutes).
When Auto mode is enabled (fiactoW default) a change from heat
to cool (or vice versa) will not occur until an opposite mode
demand has existed for 30 nmmtes. If the set point is changed, the
30 minute timer is deleted.
HEAT/COOL DEADBAND:
0 to 6 degrees, (defimlt 2°).
A nlininmm difference of 2° is enforced between heating and
cooling desired temperatures. This will allow one setting to "push"
the other to maintain this difference.
OFFSETS: This option allows calibration (or deliberate miscali-
_the temperature and humidity sensors. These ofl_ets are
added to the actual temperature humidity values (defaults 0).
Room Temp Ofi;et: -5 to +5 degrees.
Outside Temp Offset: -5 to +5 degrees.
Humidity Ofi;et: -10 to +10 percent.
CYCLES PER HOUR:
Maxinmm cycles per hour 4 (default) or 6.
Anticipator 1 to 9 (default 3).
PROGRAMMING:
On or Off (default On)
Periods Per Day 2 or 4 (defaulF4)
Programmable Fan OnOff (default Off)
SMART RECOVER-'*':
On or Ofl\ (defaulFOn)
Applies to programmable operation only. Will start recove W 90
minutes prior to schedule change in both heating and cooling.
ENGLISH/METRIC DISPLAY:
°F or °C, (del_ault °F)
RESET FACTORY DEFAULTS:
Program Schedule:
Yes_o to reset back to Energy Star defaults.
User Settings:
Yes_o to reset the user settings in the Advanced Setup.
Install Settings:
Yes_o to reset install settings in Install/Service menus.
SETUP = FURNACE:
Upon a first time start-up of the Infinity Control TM, the furnace dip
switch settings will be copied to the furnace setup menu. Any
changes can then be made from the Infinity Control TM.
AIRFLOW:
COMFORT (default)
EFFICIENCY
Selects the airflow of the furnace when heating. EFFICIENCY is
the airflow used to meet specified ratings, COMFORT is a
decreased airflow used to increase the output air temperature and
provide increased comfort.
AC AIRFLOW:
COMFORT (default)
EFFICIENCY
MAXIMUM
Selects the airflow of the furnace when cooling. COMFORT is a
decreased airflow used to improve humidity control. EFFI-
CIENCY is the airflow used to meet specified ratings. MAXI-
MIM is a fixed airflow speed of 400 CFMiton based on the
outdoor unit size.
DEHUM AIRFLOW:
NORMAL (default)
HIGH
NORMAL airflow adjustment is used &ring dehumidifying. If
d.uct sweating is an issue, selecting HIGH will increase the
dehumidifying airflow speed and reduce the sweating.
LOW HEAT RISE:
ON
OFF (default)
Set this to ON if the system contains a bypass humidifier. The ON
setting will increase the furnace low heat airflow.
STAGING:
SYSTEM (default)
FURNACE
LOW
HIGH
Controls the staging of the furnace. SYSTEM setting will allow
the Infinity Control TM to determine furnace staging. FURNACE
will allow the Furnace algorithm to control staging. LOW will
only run the low stage of furnace heat. HIGH will only run the
high stage of furnace heat.
OFF DELAY:
90 seconds (defimlt)
120 seconds
150 seconds
180 seconds
Amount of time the blower will continue to run after heating has
slmt offi
LOCKOUT TEMP:
NONE (default)
+5 to 55 degF
Appears on dual fuel systems only (fumace with heat pump).
Outside temperature above which the furnace will NOT run.