4.12.1. FUNCTION / PARAMETER LIST
Selection in bold are factory settings.
TEST
PRETRIP Enable or disable PRETRIP:
No / Yes.
TIMER
SLEEP Enable or disable Sleep Mode.
Off / On.
TEMP
RSTR Restart temperature for perishable set points in
Start/Stop:
Default Δt° : 4°C (7,2°F).
PROBE RAT
or SAT
This indicates the primary sensor that is used for
performing temperature control in the system:
Return Air / Supply Air.
SETTING
TEMP Determines temperature units on display:
Fahrenheit °F / Celsius °C
PRESS Determines pressure units on display:
Psig / Bars.
DATE Determines date format on display:
MM/DD/YYYY / DD/MM/YYYY.
BRIGHTNESS Determines display brightness.
Setting is 0 to 100.
SS PARAMETER
MINRT Minimum run time for set points in Start/Stop mode:
4 to 60 minutes, with 1 minute intervals.
Default: 4 minutes
MINOF Minimum off time for perishable set points in Start/
Stop mode:
10 to 90 minutes, with 1 minute intervals.
Special Note EMEAR Region: This parameter’s
default is based on the Operating Mode.
OVER Defines how far away the active temperature must
be away from the set point before the minimum off
time can be overridden in Start/Stop mode for per-
ishable setpoints:
Default Δt°: 4°C (7,2°F).
Special Note EMEAR Region: This parameter de-
fault is based on the Operating Mode.
MAXOF Maximum off time for perishable set points during
Start/Stop mode:
Off / 10 to 255 minutes, with 1 minute intervals.
MODE
LSCON Determines the low speed delay adjustment for Con-
tinuous:
Off / 0 to 255 minutes, with 1 minute intervals.
Default: 1 minute.
MODE
LSSS Determines the low speed delay adjustment for
Start/Stop:
Off / 0 to 255 minutes, with 1 minute intervals.
Default: 1 minute.
CITY Disable high speed in the speed control overrides:
No / Yes.
Only applies to EMEAR Region.
OTHER
DEFR The time interval between defrost cycles:
1.5 hours / 3 hours / 6 hours / 12 hours.
FRESHP Fresh Protect, used for supply air control.
NO / A / B / C (Default) / D / E.
TRANG1 This is the out-of-range temperature tolerance selec-
tion.
NO / A: 2°C (3,6°F) / B: 3°C (5,4°F) / C: 4°C (7,2°F)
62-61932-04 8