19
Detailed cooling capacities* continued
See notes on pg. 20.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85 95 105 115
CFM EWB
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
38YDA060-30 Outdoor Section in High-Speed With FK4CNB006 Indoor Section
1325
72 62.6 30.2 5.51 59.5 29.0 5.89 56.4 27.8 6.25 53.1 26.6 6.59
67 57.0 37.3 5.33 54.2 36.0 5.67 51.2 34.7 5.99 48.1 33.5 6.30
63‡‡ 53.0 36.3 5.18 50.2 35.0 5.50 47.3 33.7 5.79 44.5 32.4 6.07
62 51.9 44.2 5.14 49.1 42.8 5.45 46.4 41.5 5.74 43.5 40.2 6.02
57 48.7 48.7 5.02 46.6 46.6 5.33 44.5 44.5 5.64 42.2 42.2 5.94
1500
72 64.0 31.5 5.62 60.8 30.3 6.01 57.4 29.0 6.37 54.1 27.8 6.71
67 58.4 39.4 5.43 55.4 38.2 5.79 52.2 36.9 6.11 49.0 35.6 6.42
63‡‡ 54.3 38.4 5.29 51.3 37.0 5.61 48.3 35.7 5.91 45.3 34.4 6.20
62 53.2 47.2 5.25 50.3 45.8 5.57 47.5 44.5 5.87 44.6 43.1 6.15
57 50.9 50.9 5.17 48.7 48.7 5.49 46.3 46.3 5.81 44.0 44.0 6.12
1650
72 65.0 32.5 5.70 61.6 31.3 6.10 58.2 30.1 6.46 54.7 28.9 6.81
67 59.3 41.2 5.52 56.2 40.0 5.87 53.0 38.7 6.21 49.7 37.4 6.52
63‡‡ 55.1 40.0 5.37 52.1 38.7 5.70 49.0 37.4 6.01 45.9 36.1 6.29
62 54.2 49.7 5.33 51.2 48.3 5.66 48.3 46.8 5.97 45.5 45.2 6.26
57 52.5 52.5 5.28 50.2 50.2 5.61 47.8 47.8 5.94 45.3 45.3 6.26
1835
72 65.9 33.8 5.80 62.5 32.6 6.19 59.0 31.4 6.57 55.4 30.1 6.91
67 60.2 43.4 5.61 57.0 42.1 5.97 53.7 40.8 6.31 50.3 39.5 6.62
63‡‡ 56.0 42.1 5.47 52.9 40.7 5.80 49.8 39.4 6.11 46.5 38.0 6.40
62 55.1 52.5 5.44 52.2 51.0 5.77 49.4 49.3 6.09 46.7 46.7 6.41
57 54.2 54.2 5.40 51.8 51.8 5.75 49.3 49.3 6.09 46.7 46.7 6.41
2025
72 66.6 35.0 5.89 63.1 33.8 6.29 59.6 32.6 6.66 55.9 31.3 7.01
67 61.0 45.5 5.70 57.7 44.2 6.07 54.3 42.9 6.41 50.9 41.6 6.72
63‡‡ 56.7 44.0 5.56 53.6 42.7 5.89 50.3 41.3 6.21 47.0 39.9 6.50
62 56.1 55.2 5.54 53.3 53.3 5.88 50.6 50.6 6.22 47.9 47.9 6.55
57 55.8 55.8 5.53 53.2 53.2 5.88 50.6 50.6 6.22 47.9 47.9 6.55
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Sensible†† Power Capacity Sensible†† Power
F(A,B)4AN(F,B) 060 0.98 0.98 1.05 CJ5A/CK5A/CK5BX 060 0.96 0.91 0.98
FB4ANB 070 1.00 1.00 1.04 CK3BA 060 0.94 0.88 0.97
FC4BN(F,B) 060 0.98 0.98 1.05
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
FC4BNB 070 1.00 1.00 1.04 CC5A/CD5A/CD5BA 060 0.93 0.90 0.98
FK4CNB 006 1.00 1.00 1.00 CC5A/CD5A/CD5BW 060 0.96 0.93 0.98
CC5A/CD5A/CD5BW 060 0.98 0.97 1.02 CD3(A,B)A 060 0.93 0.90 0.99
CD5A/CD5A/CD5BA 060 0.96 0.94 1.01 CD3CA 060 0.93 0.92 0.96
CD3(A,B)A 060 0.96 0.93 1.01 CE3AA 060 0.96 0.96 1.00
CE3AA 060 0.98 0.98 1.02 CJ5A/CK5A/CK5BA 060 0.95 0.95 0.99
CJ5A/CK5A/CK5BA 060 0.96 0.96 1.02 CJ5A/CK5A/CK5BX 060 0.97 0.97 1.00
CJ5A/CK5A/CK5BN 060 0.98 0.98 1.03 CK3BA 060 0.95 0.95 0.99
CJ5A/CK5A/CK5BX 060 0.98 0.98 1.03
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
CK3BA 060 0.96 0.96 1.02 CC5A/CD5A/CD5BA 060 0.93 0.88 0.99
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5A/CD5BW 060 0.96 0.92 0.99
CC5A/CD5A/CD5BA 060 0.92 0.83 0.96 CD3(A,B)A 060 0.93 0.88 0.99
CC5A/CD5A/CD5BW 060 0.95 0.87 0.96 CD3CA 060 0.93 0.90 0.96
CD3(A,B)A 060 0.92 0.83 0.96 CE3AA 060 0.96 0.96 1.01
CE3AA 060 0.95 0.89 0.97 CJ5A/CK5A/CK5BA 060 0.95 0.94 0.99
CJ5A/CK5A/CK5BA 060 0.94 0.88 0.97 CJ5A/CK5A/CK5BX 060 0.96 0.96 1.02
CJ5A/CK5A/CK5BN 060 0.96 0.91 0.98 CK3BA 060 0.95 0.94 0.99