Dimensions
A97086
UNIT SIZE SERIES
MINIMUM MOUNTING PAD
DIMENSIONS (In.)
036 30 26 x 32
048 30 26 x 32
060 30 26 x 32
1. Allow 30 In. clearance to service side of unit, 48 In. above unit, 6 In. on one side,
12 In. on remaining side, and 24 In. between units for proper airflow.
2. Minimum outdoor operating ambient in cooling mode is 55°F, max. 125°F.
3. Maximum outdoor operating ambient in heating mode is 66°F.
4. Series designation is the 13th position of the unit model number.
5. Center of gravity .