62-10327 14
8. Examine the flexible condensate defrost drain tube (Refer to
Figure 17). The tube should be undamaged and free from
blockage or debris. It may be necessary to remove the condenser
fan for complete access.
Figure 17 Condensate Defrost Drain Tube
9. Examine external valves, coils, sight glasses, pressure
transducers as equipped per the unit model number checking for
physical damage, leaks or corrosion. Clean, repair or replace as
necessary. Refer to the operation & service manual for details on
equipped valves. Locating operation & service manuals is
explained in the Purpose section.
10. Inspect filter/drier for excessive corrosion or physical damage, and
replace as required (Refer to Figure 18). Periodic paint touch up of
the filter may be required.
Figure 18 Filter/Drier