ED Service Manual
12 04/12/10
1 O.O
0 O
BIT3 Use Unit message
0 Don't use
1 Use
BIT2 Use Total price window over
0 Don't use
1 Use
BIT 0~1 Print type
3 Don't use
2 DEP-50
1
0
2.1.2. SPAN Calibration Setting (C-3)
(1) Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays “CAL
1” message.
(2) Press [ZERO] to display “CAL-3”.
(3) Press [TARE] key and then it displays “zero ” message.
(4) Press [TARE] key and then it displays “midup” message
(5) Load middle weight (ex:1/3 full capacity) on the platform
(6) Press [TARE] key and then it displays “span ” message
(7) Load full weight on the platform
(8) Press [TARE] key and then it displays “middn” message
(9) Load middle weight (ex:1/3 full capacity) on the platform
(10) Press [TARE] key and then it display “CAL 3” message
2.1.3. Gravity Constant Value Setting (C-9)
Current gravitational Acceleration value is set to 9.7994 m/s
2
.
(1) Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays
“CAL-1” message.
(2) Press [ZERO] to display “C-9”.
(3) Press [TARE] key, and then “ G-1“ message and “9.7994” will be shown. The first
digit,”9” will blink.
(4) Input a gravitational acceleration value by using [ZERO] key.
(5) Press [TARE] key, and then “G-2“ message blinks.“9.7994” will be shown. The first
digit,”9” will blink.