SW-1S/1C/1W Service
Manual
13 2/28/2011
2.1.4. Calibration factor Setting (C-10)
Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays
“CAL-1” message.
Press [MODE] or [TARE] to move to display “C-10”.
Press [ZERO] key, and then “UNIT “message and “0” will be shown. The first digit,”0”
will blink. It means calibration unit is “kg” (0 : kg, 1 : lb)
Input a calibration unit by using [MODE] key.
Press [ZERO] key and then “CAPA“message blinks. “0015” will be shown. The first
digit,”0” will blink. It means a full-capability is “15 (calibration unit, kg or lb)”
Input a capability by using [MODE] key to change value [TARE] key to move the right.
Press [ZERO] key, and then “MId“message blinks. “0005” will be shown. The first
digit,”0” will blink. It means a mid-capability is “05 (calibration unit, kg or lb)”
Input a capability by using [MODE] key to change value [TARE] key to move the right.
Press [ZERO] key, and then “W-dP “message blinks. “3” will be shown. The first
digit,”3” will blink. It means a weight decimal point is “3 (will display 0.000)
Input a weight decimal point by using [MODE] key.
Press [ZERO] key, and then “1d “message blinks.“0.005” will be shown. The third
digit,”0” will blink. It means a division is “0.005 (calibration unit, kg or lb)”
Input a division by using [MODE] key to change value [TARE] key to move the right.
Press [ZERO] key, and then “dual “message blinks. “1” will be shown. The third
digit,”1” will blink. It means a dual interval is disable. (0 : disable, 1 : enable)”
Input a dual interval enable by using [MODE] key.
Press [ZERO] key, and then “TARE “message blinks. “0” will be shown. The third
digit,”1” will blink. It means a dual interval is disable. (0 : disable, 1 : enable)”
Press [ZERO] key to save the calibration factor and “C-10” message will be shown.
Turn off scale to save
2.1.5. Displaying Real A/D Value (C-5)
Display Raw AD