2000-22
STEP 24
Put master disconnect switch in ON position.
STEP 25
Start engine and run the engine at low idle. Run the
engine at operating temperature for approximately
five minutes to completely mix the Ethylene Glycol
and water. When the coolant is at operating
temperature, stop the engine. When engine has
cooled, check the coolant level at the reservoir.
WARNING: Hot coolant can spray out if radiator cap
is removed. To remove radiator cap: Let system cool,
turn to first notch, then wait until all pressure is
released. Scalding can result from fast removal of
radiator cap.
STEP 26
Put articulation lock in OPERATING position.