— 22 —
80 C-in line controller error 81,83,84,85,86 Reset error of C-In line controller
(128)
81 C-in line controller error 81,83,84,85,86 Receive interruption operation is not finished.
(129)
82 C-in line controller error 81 Initial error of controller. The ID No. and start up operation
(130) is not finished yet.
83 C-in line controller error 82,83,84 Token signal can not be received by some reason. Or, there
(131) are no machine in C-In line cable.
84 C-in line controller error - Transmission size is over.
(132)
85 C-in line controller error 83,85 The transmission is not finished by a noise or some reasons.
(133)
86 C-in line controller error 81 The same ID No. exists on the C-In line cable.
(134)
87 C-in line controller error - The machine does not enter the network caused a mismatch of
(135) the baud rate or some reasons.
90 C-In line protocol error 83,84,85,86 NCB (Network control block) open parameter mismatch
(144) or memory over error
91 C-Inline protocol error - NCB open error (Not used)
(145)
92 C-Inline protocol error - NCB close error (Not used)
(146)
93 C-Inline protocol error - NCB connection error (Not used)
(147)
94 C-Inline protocol error - NCB operation check error (Not used)
(148)
95 C-Inline protocol error - Header packet not received error (Not used)
(149)
96 C-Inline protocol error - NCB connection error (Not used)
(150)
97 C-Inline protocol error - NCB non connection error (Not used)
(151)
98 C-Inline protocol error - NLib(Network library) parameter mismatch error
(152)
99 C-Inline protocol error - Transmission retry over error
(153)
9A C-Inline protocol error - Reception retry over error
(154)
9B C-Inline protocol error 83,84 Packet block number mismatch error
(155)
9C C-Inline protocol error 83,84 NCB does not exist. Or, the NCB application software is
(156) stopped.
9D C-Inline protocol error 83,84 Reception memory over error.
(157)
9E C-Inline protocol error 83,84 Transmission retry over error. (Time over)
(158)
9F C-Inline protocol error 83,84 The receprion complete packet is not returned from terminal.
(159)
Error Nature of error Function Details
Code code
NOTE: The number of shown in the () is the operation error code number after code E56- of system error.

Other manuals for Casio I/O-PB-11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio I/O-PB-11 and is the answer not in the manual?

Casio I/O-PB-11 Specifications

General IconGeneral
BrandCasio
ModelI/O-PB-11
CategoryCash Register
LanguageEnglish

Related product manuals