GB
ENGLISH
GB
6
GENERAL INFORMATION
CB510/516
DESULPHATION BULK ABSORPTION FLOAT STAND-BY REFRESH
CURRENT (A)
VOLTAGE(V)
Selectoronposition “A”
Threshold
1
2
3
4
5
6
15,2V
15,2V
15,2V
Max2h
Max14,1V
Max14,4V
Max14,7V
1,5h
8h
3h
13,5V
13,8V
13,8V
Max15h
0A
0A
0A
V<13,0V
14,1V
14,4V
14,7V
Max1h
Selectoronposition “B”
Selectoronposition “C”
TheCB510/516switch-modebatterychargerhasbeenexpresslydesignedforthecaravanningand
boatingsectorandcanautomaticallycharge12V leadbatteries,withdifferentchargingvalues
accordingtothepositionsetusingtheselectorpositionedinside.
Thebatterychargerisprotectedagainstovertemperatureandthe12V outputsareprotected
againstshortcircuitandpolarityinversion.
Thehighfrequencyswitchingtechnologyallowshighperformanceswithsmalldimensionsandlimited
weight.
Phase1: – whenswitchingonthebatterycharger,onlyifneeded,thebatteryis
chargedat15.2V untilthecurrentexceeds2A orforamaximumof2hours.
Phase2: -batterychargingwithmaximumcurrentuntiltheend-of-chargevoltageisreached.
:theend-of-chargevoltageisreachedonlyifthebatteryisefficient.
Phase3: – batterychargingatcostantend-of-chargevoltageforthetimedefinedbythe
chargingline,withaprogressive reduction
Phase4: – Maintenancechargingatconstantvoltageforamaximumtimeof15hours.A high
loadleadstophase startingagain.
Phase5: – Thebatterychargerstopssupplyingpower.Itwillswitchovertothe
phase whenthebatteryvoltagegoesunder13V .
Phase6: – Thebatteryischargedatthe voltageforamaximumtimeof1h;thisphase
isdesignedtocompensateforthebatteryself-discharge.Oncecompleted,thecharging
startsagainfromthe phase.
Inmostcases,theselectorcanbesetonposition “A” forled-acidbatteries,onposition “B” forlead-
gelbatteriesandonposition “C” for AGMbatteries.
Nevertheless,itisrecommendedtoconsultthedatasheetofthebatteryinstalled.
6phaseautomaticchargingsystem
Desulphation
Bulk
Absorption
Float
Bulk
Stand-by Refresh
Refresh Bulk
Float
Note
Thepositionoftheselectormustbesetaccordingtothe charg voltagesfor
thetypeofbatteryinstalled.
current untilthechargingiscompleted.
only