Mains Electricity Connection
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY
BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE
POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A
3A FUSE.
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C. and
who will comply with the I.E.E. and local
regulations.
The wires in the mains lead of this
appliance are coloured in accordance
with the following code:
BLUE = NEUTRAL, BROWN = LIVE, GREEN+YELLOW = EARTH
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals
connecting to the fused spur, proceed as follows:
The wire which is coloured blue must be connected to the terminal
marked N (Neutral), or coloured black.
The wire which is coloured brown must be connected to the
terminal marked L (Live), or coloured red.
The wire which is coloured green and yellow must be connected
to the terminal marked E (Earth) or coloured green or green and
yellow.
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3 AMP FUSE