Assembly and electrical connection should be carried out by
competent personnel.
When installing this product we recommend you seek the help of
another individual.
IMPORTANT: THIS APPLIANCE IS A CLASS II APPLIANCE
(DOUBLE INSULATED) AND IS NOT INTENDED TO BE EARTHED.
DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR.
Do not mount the isolation switch behind the chimney section. It is a
requirement that you must be able to isolate the extractor from the
mains electrical supply after installation.
This appliance is intended to be connected to the mains electrical
supply by means of an isolation switch and fused spur and is
intended to be protected by a 3A fuse. The use of a 13A fuse can
cause damage to the internal wiring in the event of a fault, and may
also invalidate the warranty.
Electrical Information
Mains electrical voltage: 230 – 240Vac, 50Hz
Total rated power consumption: 290W
Troubleshooting
If your extractor is not working:
1. Check that the mains supply has not been switched o.
2. Check that the fuse in the spur has not blown.