To remove the grease filters
1. Pull open the handle on each grease filter as shown in fig. 2. It will
release at the handle side.
2. Lower the grease filter to remove it completely.
To replace the grease filters
Repeat the steps above in reverse order.
Please note: Cleaning the grease filters in a dishwasher may lead to
discolouration. This is normal and does not constitute a fault with the
appliance.
Changing the charcoal filter (re-circulating only)
When the display flashes alternating the speed selected with the
letter “F”, the charcoal filters must be replaced. After the charcoal
filter has been replaced, the electronic memory must be reset by
touching key “A” for approximately five seconds, until the letter “F”
stops flashing.
To attach a new charcoal filter, first remove the grease filters as
described above. Then oer up the charcoal filter to the side of the
motor as shown in fig. 3 and turn it clockwise until it locks into place.
Repeat with the other charcoal filter on the other side of the motor.
Then replace the grease filters.