35
Problem Possible Cause Remedy
After turning on, the
appliance turns itself
off.
You have not used
any appliance
function.
When turn on the appliance, use it
without delay.
The cooking zone has
turned itself off.
The maximum operat-
ing time has been
reached.
Activate the cooking zone again and
set the heat setting.
Noises are heard
during cooking.
Normal operation of the appliance. The noises emitted
depend on the pots used and the heat setting.
The “h” or “H” symbol
is shown on the
cooking zone display.
Normal operation of the appliance. The “h” or “H” symbols
indicate that the cooking zone is warm/hot and extra care is
required.
F0 is shown on the
cooking zone display.
Supplied voltage too
low.
Contact your electricity supplier.
F1 is shown on the
cooking zone display.
Supplied voltage too
high.
Contact your electricity supplier.
F2 is shown on the
cooking zone display.
Electronic protection
has been activated.
Check that the cooling fan opening is
not obstructed.
F3 is shown on the
cooking zone display.
The cooking zone
protection has been
activated.
Remove the cookware from the cook-
ing zone and wait until the F3 symbol
goes off.
F4 , F5, F6, F7, F8 or F9
is displayed on the
cooking zone display.
External power
interference.
Unplug the appliance from the power
outlet for 120 seconds or disconnect
the miniature circuit breaker (MCB) or
fuse in your home electrical
distribution
box.
Cracked ceramic plate Danger! Immediately unplug the appliance from the power sup-
ply or disconnect the miniature circuit breaker (MCB) or fuse
in your home electrical distribution box. Refer the repair to the
nearest service centre.

Related product manuals